摘要
对水泥稳定类基层材料干燥收缩的机理、影响因素进行了详细而全面的分析,并在此基础上提出了有效的预防措施,以尽量减少水泥稳定类基层材料的干缩裂缝。
This article carries out overall analysis on the mechanism and influencing factors of dry shrinkage in cement stabilized base materials, and proposes effective preventive measures on the basis of the analysis, in order to redUCe dry shrinkage crack in cement stabilized base materials.
出处
《山西建筑》
2007年第1期269-270,共2页
Shanxi Architecture
关键词
水泥稳定基层
干缩裂缝
含水量
cement stabilized base course, dry shrinkage crack, water content