针对住宅建筑现浇楼板容易产生裂缝的现象,在分析其成因的基础上从设计、材料和施工方面提出了综合防治措施,以杜绝或减少现浇楼板裂缝的发生。
According to cracks produced in spot-cast concrete floor-slab, based upon cause's analysis from three aspects: design, material and oonstruction comprehensive prevention and treatment measures are proposed in order to reduce cracks and ensure engineering quality.