期刊文献+

一体式膜-生物反应器同步硝化反硝化中试试验 被引量:4

PILOT-SCALE TEST OF SIMULTANEOUS NITRIFICATION AND DENITRIFICATION (SND) OF AN INTEGRATED MEMBRANE BIOREACTOR
下载PDF
导出
摘要 当污泥浓度维持在19~20g/L时,一体式平板膜-生物反应器运行112d,通量稳定在25.2~25.7L/(m2.h),运行过程除正常曝气以保持对膜进行水力冲刷外没有进行任何物理和化学清洗。试验考察不同DO浓度对同步硝化反硝化效果的影响,结果表明,反应器内有较好的硝化反硝化效应,当温度在18~12℃变动时,膜生物反应器的硝化反硝化效果基本不受温度的影响。 The integrated flat plate MBR was operated at membrane flux 25.2~25.7 L/(m^2·h) for 112 days with MLSS concentration 19~20 g/L.During the operation,MBR was not cleaned physically or chemically except normal aeration which was used to scour membrane surface.The effect of DO concentration on simultaneous nitrification and denitrification (SND) in the MBR was investigated.Test results indicated that there was a good SND effect in MBR; and SND effect was not affected by temperature variations in range of 18~12 ℃.
出处 《环境工程》 CAS CSCD 北大核心 2007年第1期13-15,共3页 Environmental Engineering
基金 国家高技术发展计划"863"项目(2002AA601220) 教育部科学技术研究重点(重大)项目资助(03070)
关键词 一体式膜-生物反应器 平板膜 同步硝化反硝化 污水处理 integrated membrane bioreactor, flat plate membrane,simultaneous nitrification & denitrification and wastewater treatment
  • 相关文献

参考文献8

  • 1齐唯,李春杰,何义亮.浸没式膜生物反应器的同步硝化反硝化效应[J].中国给水排水,2003,19(7):8-11. 被引量:33
  • 2邹联沛,刘旭东,王宝贞,范延臻.MBR中影响同步硝化反硝化的生态因子[J].环境科学,2001,22(4):51-55. 被引量:65
  • 3国家环保局.水和废水监测分析方法[M].北京:中国环境科学出版社,1989.260-263.
  • 4Berthold Günder,Karlheinz Krauth.Repalcement of secondary clarification by membrane separation-Results with tubular,plate and hollow fiber modules.Wat.Sci.Tech,1999,40(4-5):311-320.
  • 5Klangduen Pochana,Jürg Keller.Study on factors affecting simultaneous nitrification and denitrification(SND).Wat.Sci.Tech,1999,39 (6):61-68.
  • 6Klangduen Pochana,Jürg Keller.Model development for simultaneous nitrification and denitrification.Wat.Sci.Tech,1999,39 (1):235-243.
  • 7E.L.柯斯乐,王宇新,姜忠义译.扩散-流体系统中的传质(第二版).北京:化学工业出版社,2002.
  • 8高廷耀,周增炎.生物脱氮工艺中的同步硝化反硝化现象[J].给水排水,1998,24(12):6-9. 被引量:83

二级参考文献7

  • 1郑兴灿 李亚新.污水脱磷除氮技术[M].北京:中国建筑工业出版社,1998..
  • 2Muller E B,Stouthamer A H,van Verseveld H W, et al.Aerobic domestic wastewater treatment in a pilot plant with complete sludge retention by crossflow filtration[J].Wat Res, 1995,29(4) : 1179 - 1189.
  • 3Berthold Gunder,Karlheinz Krauth, et al. Replaecnnent of secondary darification by mcnnbrane separation - results with tubular, plate and hollow fibre modules[J]. Wat Sci Tech, 1999,40(4 - 5) :311 - 320.
  • 4高廷耀,城市给排水,1998年,24卷,12期,6页
  • 5郑兴灿,污水脱磷除氮技术,1998年,51页
  • 6张自杰,排水工程下册(第3版),1996年,276页
  • 7高廷耀,周增炎.生物脱氮工艺中的同步硝化反硝化现象[J].给水排水,1998,24(12):6-9. 被引量:83