期刊文献+

除草剂苯噻草胺的RP-HPLC测定 被引量:2

RP-HPLC Determination of Mefenacet
下载PDF
导出
摘要 采用高效液相色谱法,以甲醇和水(含0.3%冰醋酸)为流动相,使用反相色谱柱和紫外检测器对除草剂苯噻草胺进行测定。方法的标准偏差0.29,变异系数0.79%(n=6),线性关系决定系数R2=0.9998,添加回收率100.9%~107.1%,检测限0.1mg·L-1,结果令人满意。 A high performance liquid chromatography method of mefenacet was established on a ZORBAX SB-C18 column ( 250×4.6mm, 5μm) and variable wavelength detector, with the mobile phase of methanol and water (involved 0.3% acetic acid). The standard deviation was 0.29 and the variation coefficient was 0.79%(n=6). The R2 of the linear correlation was 0.9998 and the recoveries were ranged from 100.9% to 107.1%. The results were satisfying.
作者 褚明杰
出处 《安徽化工》 CAS 2007年第1期67-68,共2页 Anhui Chemical Industry
基金 校长青年基金资助项目(2005)
关键词 苯噻草胺 高效液相色谱 mefenacet high performance liquid chromatography
  • 相关文献

参考文献3

二级参考文献3

  • 1张敏恒.农药商品手册[M].辽宁:沈阳出版社,1989.747,749.
  • 2李子彬.中国化工产品大全(下卷)[M].北京:化学工业出版社,1994.315.
  • 3姜欣,侯春青,李世忠.苯噻草胺的分析方法[J].农药,1999,38(7):9-9. 被引量:8

共引文献9

同被引文献7

引证文献2

二级引证文献3

相关作者