1Toohey,R.,Palmer,E.,Anderson,L.,Berger,C.et al.Current status of whole-body counting as means to detect and quantify previous exposures to radioactive materials[J].Health Phys,1991,60(1):7-42.
2Webb,J.L.and Kramer,G.H.An evaluation of germanium detectors employed for the measurement of radionuclides deposited in lungs using an experimental and Monte Carlo approach[J].Health Phys,2001,81(6):711-719.
3Kramer,G.H.,Burns,L.C.and Yiu,S.Lung counting:evaluation of uncertainties in lung burden estimation arising from a heterogeneous lung deposition using Monte Carlo code simulations[J].Radiat.Prot.Dosim,1997,74(3):173-182.
4Wahl,W.,Haninger,T.,Kucheida,D.et al.Study of long-term radon progeny in humans for retrospective evaluation of radon exposures[J].J.Radioanal.Nucl.Chem,2000,243(2):447-450.
5Borisov,N.,Franck,D.,de Carlan,L.et al.A new graphical user interface for fast construction of computation phantoms and MCNP calculations:application to calibration of in-vivo measurement systems[J].Health Phys,2002,83(2):272-279.
6Jones DG.A realistic anthropomorphic phantom for calculating organ doses arising from external photon irradiation[J].Radiat Prot Dosim,1997,72(1):21-29.
7I.Smiljanic,F.W.Schultz.Applicability and limitations of the adam mathematical phantom with respect to radiological protection[J].Radiation Protection Dosimetry,2004,111(1):89-92.
8Xu XG,Chao TC,Bozkurt A.VIP-Man:An image-based whole-body adult male model constructed from color photographs of the visible human projext for multi-particle Monte Carlo calculations[J].Health Phys,2000,78(5):476-486.
9Ishikawa,T.,Matsumoto,M.and Uchiyama,M.A calibration method for whole-body counters,using Monte Carlo simulation[J].Radiat.Prot.Dosim,1996,64(4):283-288.
10Fisenne,I.M.Long Lived Radionuclides in the Environment,in Food and in Human Beings,Tutorial Session 4[A].in:Fifth International Symposium on the Natural Radiation Environment,Commission of the European Communities Report EUR 14411,1993:185-255.
6Toohey RE.Internal dose assessment in radiation accidents.Radiat Prot Dosim,2003,105 (1-4):329-331.
7IAEA.Rapid monitoring of large groups of internally contaminated people following a radiation accident.IAEA-TECDOC-746.Vienna:IAEA,1996.
8Muikku M,Rahola T.Improvement of the measuring equipment used in the assessment of internal doses in emergency situations.Radiat Prot Dosim,2007,127(1-4):277-281.
9Singh IS,Suri M MK,Vidhani JM,et al.Development of an automated shielded chair whole-body monitor.Radiat Pro Dosim,2002,102 (2):145-151.
10Franck D.Potential of modern technologies for improving intemal exposure monitoring.Radiat Prot Dosim,2007,127 (1-4):233-239.