摘要 提出在中央空调温湿度控制系统中,基于常规模糊PID控制器,引入积分分离PID控制思想.当系统调节开始时由于系统误差较大,系统的积分系数为零,系统的控制主要由模糊PD控制来实现;当系统误差较小时加入积分控制环节,系统切换为模糊PID控制,从而改善和提高系统的控制性能. This paper proposes to introduce the theory of integral apart PID control in the central air-conditioning's temperature and humidity control based on the routine fuzzy PID controller. While the integral modulus is zero because the system error is big at the beginning of system adjustment, the control mostly depends on the Fuzzy PD control. When the error is smaller, the integral control taehe is added, the system switches to Fuzzy PID control so as to improve the capability of the system.
作者 常继彬
出处 《重庆工学院学报》 2007年第1期117-119,127,共4页 Journal of Chongqing Institute of Technology
关键词 积分分离PID控制 模糊控制 中央空调 温湿度控制 integral apart PID control fuzzy control central air-conditioning temperature and humidity control
  • 相关文献

参考文献1

二级参考文献3

  • 1赵建平.中央空调数字控制器的设计与研究:硕士学位论文[D].上海大学,1998.
  • 2Huang, S - H., and R. M. Nelson. 1994 Rule development and adjustment strategy of a fuzzy logic controller for an HVAC system:Part ene - Analysis[ J ]. ASHRAE Transactions 100(1) : 841 - 850.
  • 3李土勇.模糊控制和智能控制理论与应用[M].哈尔滨工业大出版社,1990年12月第一版..