摘要 在地震发生后,供水管网一般处于渗漏工作状态。为了评价城市供水管网的抗震能力,需要进行震后带渗漏供水管网的水力分析,对震后供水管网的流分析方法进行了改进,并建立了震后带渗漏供水管网的水力分析模型,通过连通性分析和连续性方程求解,计算得到震后节点的供水量和节点压力,进而评价供水管网的地震功能。另外,以某供水管网为例,演示了该方法的可行性。为供水管网的抗震设计、城市供水系统的抗震能力预测、提高震后救灾恢复的效率具有重要的指导作用。 When an earthquake occurred, leakage phenomena usually occur in water supply network. In order to evaluate the seismic performance of the water supply network, it is necessary to conduct the service performance analysis of the water supply network based on pipe leakage model. The analysis method is presented and discussed in detail in this paper, and a hydraulic leakage model is also built. Through the connectivity analysis and the continuity equation solution, the node flows and node water heads can be obtained, and finally the service performance of the water supply network can be evaluated. In addition, an example of the water supply network is presented to illustrated and discussed in detail. All of above may be applied to practice, such as earthquake design, earthquake damage forecast and earthquake mitigation analysis of practical water supply network.
出处 《工程力学》 EI CSCD 北大核心 2007年第3期142-146,125,共6页 Engineering Mechanics
基金 国家自然科学基金赞助项目(50478094)
关键词 供水管网 渗漏模型 地震失效 功能分析 抗震设计 water supply network leakage model seismic failure seismic performance analysis earthquake design
  • 相关文献

参考文献7

  • 1陈玲俐,李杰.供水管网渗漏分析研究[J].地震工程与工程振动,2003,23(1):115-121. 被引量:34
  • 2陈玲俐,李杰,叶志明.震后特殊供水状态下的供水管网水力分析[J].自然灾害学报,2004,13(3):89-94. 被引量:15
  • 3Markov.An evaluation of seismic serviceability of water supply networks with application to san francisco auxiliary water supply system[R].NCEER-94-0001,National Center for Earthquake Engineering Research,State University of New York at uffalo,Buffalo,NY,1994.
  • 4高惠瑛.基于GIS供水系统地震反应分析[D].哈尔滨:中国地震局工程力学研究所,2003.
  • 5李昕.供水系统可靠性分析[D].大连:大连理工大学.2001.
  • 6Jianwen Liang.Online detection and location of seismic damage in a water distribution system[A].13th WCEE[C].Vancouver,B.C.,Canada,2004,paper No.1177.
  • 7侯忠良.地下管线抗震计算方法与工程应用[C].冶金工业部建筑研究总院防灾抗震工程研究所,1991.87~ 94.

二级参考文献5

共引文献45

同被引文献81

引证文献16

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部