期刊文献+

远端保护装置在冠心病介入治疗中的应用

Application of distal protection device during percutaneous coronary intervention in coronary heart disease
下载PDF
导出
摘要 随着冠心病介入治疗的普及和发展,远端保护装置的应用越来越多。本文就远端保护装置在冠心病介入治疗中的应用予以综述。 With the pervasion and development of percutaneous coronary intervention in coronary heart diease,the application of distal protection device is increased. This article reviews the application of distal protection device during percutaneous coronary intervention in coronary heart diease.
作者 张成 王伟
出处 《中国心血管杂志》 2007年第1期67-69,共3页 Chinese Journal of Cardiovascular Medicine
关键词 远端保护装置 冠心病 介入治疗 Distal protection device Coronary heart disease Percutaneous coronary intervention
  • 相关文献

参考文献11

  • 1Topol EJ,Yadav JS. Recognition of the importance of embolization in atherosclerotic vascular disease[J]. Circulation, 2000,101 : 570-580.
  • 2Henriques JP, Zijlstra F, Ottervanger JP, et al. Incidence and clinical significance of distal embolization during primary angioplasty for acute myocardial infarction[J ]. Eur Heart J, 2002,23:1112-1117.
  • 3王乐丰,杨新春,佟子川,徐立,吴兆苏,张维君,王红石,邹阳春,葛永贵,王立中,李惟铭,周旭,连勇,栾与英.远端保护装置Angioguard^(TM)在急性心肌梗死急诊经皮冠状动脉介入治疗中的应用[J].中国介入心脏病学杂志,2003,11(3):120-122. 被引量:11
  • 4Stone GW, Webb J, Cox DA, et al. For the Enhanced Myocardial Efficacy and Recovery by Aspiration of Liberated Debris (EMERALD) Investigatons[J]. JAMA,2005,293:1063-1072.
  • 5Baim DS, Wahr D, George B, et al. Randomized trail of a distal embolic protection device during percutaneous intervention of saphenous vein aorta-coronary bypass grafts [ J ]. Circulation,2002,105 : 1285-1290.
  • 6Grube E,Gerckens U,Yeung AC,et al. Prevention of distal embolization during coronary angioplasty in saphenous vein grafts and native vessels using porous filter protection[J ]. Circulation,2001,104:2436-2441.
  • 7Stone GW,Rogers C,Hermiller J,et al. Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts[J ]. Circulation,2003,108: 548-553.
  • 8Holmes DR,Lennon RJ, Rihal CS, et al. Applicability of distal protection fro aortocoronary vein graft interventions in clinical practice[J]. Catheter Cardiovasc Interv,2004,63:148-151.
  • 9Wu CJ, Yang CH, Fang CY, et al. Six-month angiographic results of primary angioplasty with adjunctive PercuSurge Guard-Wire device support: evaluation of the restenotic rate of the target lesion and the fate of the distal balloon occlusion site [J ].Catheter Cardiovasc Interv, 2005,64: 35-42.
  • 10Yamaguchi K, Hiasa Y, Takahashi T. Formation of a coronary artery aneurysm after inflation of a PercuSurge GuardWire distal protection balloon[J ]. Catheter Cardiovasc Interv, 2005,64: 82-84.

二级参考文献9

  • 1Morishima 1, Sone T, Okumura K, et al, Angiographic no-reflow phenomenon as a predictor of adverse long-term outcome in patients treated with percutaneous transluminal coronary angioplasty for first acute myocardial infarction. JACC, 2000,36:1202-1209.
  • 2Tanaka A, Kawarabayashi T, Nishibori Y, et al, No-reflow phenomenon and lesion morphology in patients with acute myocardial infarction. Circulation, 2002, 105:2148-2152.
  • 3vHof AM J, Liem A, Suryapranata H, et al, Angiographic assessment of myocardial reperfusion in patients treated with primary angioplasty for acute myocardial infarction: myocardial brush grade. Circulation,1998,97 : 2302-2306.
  • 4Iwakura K, Ito H, Nishikawa N, et al, Early temporal changes in coronary flow velocity patterns in patients with acute myocardial infarction demonstrating the “no-reflow” phenomenon. Am J Cardiol,1999,84:415-419.
  • 5Yamada DM, Topol EJ. Microvascular embolization in acute coronary syndromes. Acut Cor Syn, 2001,4:1-17.
  • 6Rezkalla SH, Kloner RA, No-reflow phenomenon. Circulation, 2002,105 : 656-662.
  • 7Michaels AD, Gibson CM, Barton HW. Microvascnlar dysfunction in acute myocardial infarction: focus on the roles of platelet and inflammatory mediators in the no-reflow phenomenon. Am J Cardiol,2000,85:50B-60B.
  • 8Bain DS, Wahr D, George B, et al, Randomized trial of a distal embolic protection device during percutaneous interven of saphenous vein aorto-coronary bypass grafts. Circulalion, 2002,105:r13-r18.
  • 9U.S. SAPPHIRE Study Group. Preliminary results of carotid stenting with ANGIOGUARD XP emboli protection guidewire vs. surgery for carotid artery blockages in high risk patients. AHA, 2002,11, chicago,IL.

共引文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部