摘要 针对信息系统防雷工作中经常出现电源N-PE(中性线与保护地)电压过大而影响设备正常工作的情况,分析了N-PE电压产生的机理,它们是纯电阻引起的N-PE电压、地电路环路引起的N-PE电压和公共阻抗干扰引起的N-PE电压;分讨论了引起N-PE电压的常见原因以及降低N-PE电压的常用方法。 An analysis is made of the mechanisms of high N-PE voltage formation, which are induced by pure resistance, earth circuit loop, and common impedance, in connection with the common faults resulted from high N-PE (neutral and protected earth conductor) voltage encountered in the operational lightning protection for the information system. The common causes for high N-PE voltage and the methods for reducing N-PE voltage are also discussed.
出处 《气象科技》 2007年第1期130-132,共3页 Meteorological Science and Technology
关键词 N—PE电压 地电路环路 公共阻抗 N-PE voltage, earth circuit loop, common impedance
  • 相关文献

参考文献3

  • 1王德言,李雪佩,宏育同等.建筑物电子信息系统防雷技术规范(GB50343—2004)[S].北京:中国建筑工业出版社,2004:67—70.
  • 2谢征.卫星通信小型地球站雷电防护技术[J].气象科技,2005,33(3):275-277. 被引量:9
  • 3林维勇.建筑物防雷设计规范(GB50057—94)(2000版)[S].北京:中国计划出版社,2001.

二级参考文献4

  • 1徐建平().休斯网络系统公司VSAT卫星通信小站技术手册[M].北京:气象出版社,1995..
  • 2.GB50057-94建筑物防雷设计规范[M].北京:中国计划出版社,2001.27.
  • 3.YD2011-93微波站防雷与接地设计规范[M].北京:北京邮电学院出版社,1994..
  • 4.YD5028-96国内卫星通信小型地球站 VSAT 通信系统工程设计暂行规定[M].北京:北京邮电学院出版社,1997.36-37.