摘要
通过电阻温度测试系统来测试由La0.67Ca0.33MnO3多晶材料制成的敏感电阻,发现La0.67Ca0.33MnO3敏感电阻的电阻值不仅随着温度呈线性变化,而且也随着湿度呈线性变化。将封装后的La0.67Ca0.33MnO3敏感电阻与标准Pt100热敏电阻进行测温比较,相对误差为0.2%。
The resistance-temperature characteristic of the sensitive resistance prepared by polycrystalline La0.67Ca0.33MnO3 was tested through the system for testing resistance-temperature. We discovered that the resistance value of the La0.67Ca0.33MnO3 sensitive resistance exhibits linear change not only along with temperature hut also with humidity. After the hermetically sealed sensitive resistance of La0.67Ca0.33MnO3 was compared with the standard Ptl00 thermistor to measuretemperature, the relative error is 0.2%.
出处
《山东陶瓷》
CAS
2007年第1期10-14,共5页
Shandong Ceramics
关键词
LCMO
敏感电阻
热敏与湿敏
LCMO
Sensitive Resistor
Thermal-- Sensitivity And Humidity-- Sensitivity