摘要
袖珍实时心电图液晶显示仪是为门诊、急诊及查房时临床医师及时发现病人一过性心律失常、心肌缺血使用。该机体积小,使用方便,具有快速显示、床旁监护、冻结、贮存回放等功能。经临床试用100例,图形清晰不失真,与对照心电图比较,P波、QRS综合波及ST段无明显差异。
In order to diagnose a twinkling arrhythmia and myocardial ischemia clinically in time,a pocket real-time electrocardiogram liquid-crystal monitor was developed. It can be used by physicians for out-pa tient.the rounds of the wards,and first aid. It is charicterized by quick display,bedside monitoring,functions of freeze,.storage and sampling. Thie result of inonitoring in I 00 cases was not different from control electro cardiograms in P waves,QRS complexes and ST segments.
出处
《医疗卫生装备》
CAS
1996年第2期9-10,共2页
Chinese Medical Equipment Journal