低温核供热堆辐射防护安全准则 被引量:1

Guideline of radiation protection and safety for low temperature thermo Supply nuclear reactors
原文传递
导出
摘要 作者提出了低温核供热堆辐射防护安全准则的建议,即①要求半径50km范围内加权人口不超过106;②禁区半径为250m;③限制发展区半径2km;④低温核供热堆正常运行期间,由于放射性向环境释放所致公众个人剂量(全身或有效)不应超过0.1mSv/a,集体剂量不超过100man·Sv/a;⑤低温核供热堆事故期间,公众个人剂量不超过5mSv,集体剂量不超过1000man·Sv;⑥低温核供热堆正常运行期间,放射性流出物(气体、液体)的释放量不应超过国标GB6249规定值的2/5;⑦热网水中的放射性活度不应超过0.37Bq/L;⑧建议应急状态分为三级,即应急待命、厂房应急和场区应急。 A proposal on the guideline of radiation protection and safety for a low temperature thermo supply nuclear reactor has been put forward,namely:(1) Weighted population in a 50km radius region should not exceed 106;(2) The radlus of exclusion area is 250m;(3)The radius of restricted development area is 2km;(4)The individual dose(whole body or effective) to publiccaused by release of radioactivity to environmemt during normal operation of a low temperature thermo supply nuclear reactor should not exceed 0.1mSv/a,and the collective dose should not exceed 100man.Sv/a;(5) Indvidual dose(whole body or effective) during an accident of a low temperature thermo Supply nuclear reactor should not exceed 5mSv,and the collective dose should not exceed 1000man.Sv;(6) For a low temperature thermo Supply nuclear reactor during normal operation the release of radioactive effluent should not exceed two-fifths of the value defined in national standard GB6249;(7) The radionuclide concentrationin the water of heating loop should not exceed 0.37Bq/l;(8)Three emergency grades are proposed:namely,emergency standby,plant emergency and site emergency.
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 1996年第4期260-264,共5页 Chinese Journal of Radiological Medicine and Protection
基金 国家"八五"重点攻关科技项目
关键词 辐射防护 安全准则 低温核供热堆 Guideline,radiation protection,safety,low temperature thermo supply reactor
  • 相关文献

参考文献2

  • 1吴柏龄,1995年
  • 2肖宏才,1982年

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部