摘要 研究了不同浓度下乙二酸对元素电感耦合等离子体质谱(ICP—MS)行为的影响。结果表明,低浓度乙二酸对所分析元素的灵敏度具有显著的增敏效应,尤其是对电离电位在9~11eV的Be,Zn,Se,As,Sb,Hg等高电离电位元素。作为一种增敏剂,乙二酸可以补偿由于无机基体的存在对高电离电位元素所产生的信号抑制现象,从而提高其分析灵敏度2~10倍。采用所建立的方法测定了水标准物质中的Be,Zn,Se,As,Sb和Hg,其测定结果与标准物质的认定值基本一致。 The influence of different concentration of oxalic acid on elemental inductively coupled plasma mass spectrometry (ICP-MS) has been investigated. It has been proved that the sensitivity of analytes can be significantly enhanced by adding small amounts of oxalic acid, especially for the elements with ionization potential between 9 and 11 eV. Oxalis acid, as an enhancement agent, can be used to compensate the signal depression caused by inorganic matrix and to improve the detection limits by about 2-10 times, for the hard-to-ionize elements in ICP-MS determination. The method has been used to determine Be, Zn, Se, As, Sb and Hg in water certified reference materials. The analytical results are very close to the certified values.
出处 《冶金分析》 EI CAS CSCD 北大核心 2007年第2期13-17,共5页 Metallurgical Analysis
基金 Hunan provincial Natual Science Foundation(No.02JJY3007,03JJY5001)
关键词 电感耦合等离子体质谱 乙二酸 增敏效应 高电离电位元素 inductively coupled plasma mass spectrometry oxalic acid enhancement effect hard-to-ionize elements
  • 相关文献

参考文献12

  • 1Sakao S, Uchida H. Determination of trace elements in shellfish tissue samples by inductively coupled plasma mass spectrometry [J]. Anal. Chim. Acta, 1999, 382: 215-263.
  • 2Cao S, Chen H, Zeng X. Determination of mercury in biological samples using organic compounds as matrix modifiers by inductively coupled plasma mass spectrometry [J]. J. Anal. Atom. Spectrom., 1999,(14): 1183-1186.
  • 3杨金夫,曾宪津,黄本立.有机试液的电感耦合等离子体原子发射光谱分析 Ⅰ.实际应用的若干方面[J].分析化学,1991,19(3):362-369. 被引量:6
  • 4李冰,尹明.乙醇在电感耦合等离子体质谱中的增强效应研究[J].光谱学与光谱分析,1995,15(5):35-40. 被引量:36
  • 5J Goossens, F Vanhaecke, L Moens, et al. Elimination of interferences in the determination of arsenic and selenium in biological samples by inductively coupled plasma mass spectrometry[J]. Anal. Chim. Acta, 1993, 280: 137-142.
  • 6Hutton R C. Application of inductively coupled plasma source mass spectrometry to the determination of trace metals in organics [J]. J. Anal. Atom. Spec trom. , 1986, 1: 259-263.
  • 7Hill S J, Ford M J, Ebdon L. Investigation into the application of methane addition to the nebulizer gas in inductively coupled plasma mass spectrometry for the removal of polyatomic interferences [J]. J. Aanl. Atom. Spectrom. , 1992, 7: 1157-1165.
  • 8Hu Z, Hu S, Gao S, Liu Y, Lin S. Volatile organic solvent-induced signal enhancements in inductivelycoupled plasma-mass spectrometry., a case study of methanol and acetone [J ]. Spectrochim. Acta 13,2004, 59.. 1463-1470.
  • 9Longerich H P. Effect of nitric acid, acetic acid and ethanol in inductively coup led plasma mass spectrometry ion signals as a function of nebuliser gas flow, with implication on matrix suppression and enhancements [J]. J. Anal. Atom. Spectrom. , 1998, 4:665 -667.
  • 10Llorente I, Gomez M, Camara C. Improvement of selenium determination in water by through use of organic compounds as matrix modifiers [J]. Spectromchim. Acta B, 1997, 52: 1825-1838.

二级参考文献20

  • 1杨金芳,化学学报,1990年,48卷,903页
  • 2黄本立,Spectro Chim Acta,1988年,43B卷,381页
  • 3杨金夫,分析化学,1988年,16卷,198页
  • 4朱世盛,分析化学,1988年,16卷,556页
  • 5綦文娣,稀有金属,1988年,7卷,1期,59页
  • 6张卓勇,分析化学,1987年,15卷,801页
  • 7金泽祥,分析试验室,1987年,6期,3页
  • 8金泽祥,分析试验室,1987年,6期,6页
  • 9陈振宁,分析化学,1986年,14卷,641页
  • 10辛仁轩,分析化学,1984年,12卷,787页

共引文献40

同被引文献12

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部