期刊文献+

基体未分离高分辨电感耦合等离子体质谱法测定钢中痕量元素 被引量:23

Determination of trace elements in steel by high resolution inductively coupled plasma mass spectrometry without matrix separation
下载PDF
导出
摘要 为了满足钢铁产品日益严格的质量需求,将钢铁产品中痕量元素的测定下限降低至μg/g级也日显重要。本研究工作利用高分辨率的等离子质谱仪快速、准确测定了钢中μg/g级的B,Al,P,Cr,Pb,Sn,Sb,As,Bi等多种元素。钢铁样品用硝酸、盐酸、氢氟酸在电热板上加热或微波消解,溶液经稀释后未经基体分离,未加内标直接用电感耦合等离子体质谱法(ICP—MS)测定。该方法检测下限:P为0.145μg/g,其余元素低于0.1μg/g。精密度好,相对标准偏差(n=10):Bi为10.5%,其余元素小于5%。回收率:As为81%~120%,其余元素86%~106%。标样的测定值与认定值吻合,方法非常适合测定钢铁产品中痕量元素。 necessary In to study, trace mined fast order to meet strict increasing reduce the determination low I elements like B, AI, P, Cr, Pb, S and accurately. Steel samples ly quanlity requirement imits of trace elements n, Sb, As, Bi in μg/g or were dissolved with in iron and steel production, it is in steel to the μg/g order. In this sub μg/g level in steel were deternitric acid, hydrochloric acid and hydrofluoric acid by electrothermal heating or microwave digestion. After diluted, the solution was measured by high resolution inductively couled plasma-mass spectrometry(HR-ICP-MS) without any matrix separation or internal standard. It had good precision giving RSDs(n=10) of below 5% except for 10.5~ of Bi. The detection limits of the method was lower than 0.1 μg/g,except for 0. 144 μg/g of P. The recoveries of 86%--10% were satisfied,except for 81%--120% of As. The measured values tally with the certified values. The method is extraordinary suitable for the determination of trace elements in steel.
出处 《冶金分析》 EI CAS CSCD 北大核心 2007年第2期18-23,共6页 Metallurgical Analysis
关键词 电感耦合等离子体质谱法 钢铁 痕量元素 基体未分离 inductively coupled plasma-mass spectrometry steel trace elements without matrix separation
  • 相关文献

参考文献6

  • 1A G Coedo,M T Dorado,I Padilla. Evaluation of different sample introduction approaches for the determination of boron in unalloyed steels by inductively coupled plasma mass spectrometry[J]. Spectrochimica. Acta: Part B,2005,60..73-79.
  • 2Finkeldei S,Staats G. ICP-MS- a powerful analytical technique for the analysis of traces of Sb, Bi, Pb, Sn and P in steel[J]. Fresenius' J Anal. Chem. , 1997, 359:357-360.
  • 3Fujimoto K, Shimura M, Satoh S. Determination of trace amounts of antimony and boron in high-purity iron and steel by isotope dilution/inductively coupled plasma mass spectrometry[J]. Materials Transactions, 2002,43(2) : 101 - 104.
  • 4Hasegawa S I, Ide K, Kobayashi T, et al. Analysis of the Trace Amount of Metallic Elements in Iron and Steels Using the Microwave Decomposition by ICP- AES and ICP-MS[J]. Tetsu- to- Hagane (Journal of the Iron and Steel Institute of Japan) ,2003,89(9):895 -899.
  • 5Hu Jingyu,Wang Haizhou. Determination of trace elements in superalloy by ICP-MS[J]. Microchimica Acta,2001,137(3-4) :149-155.
  • 6Hu Jingyu, Liu Zheng, Wang Haizhou. Determination of trce siliver in superalloys and steels by inductively coupled plasma-mass spectrometry[J]. Anal. Chim. Acta,2002,451:329-335.

同被引文献635

引证文献23

二级引证文献128

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部