大型储罐罐底阴极保护检测数据及其分析 被引量:13

Analysis on the CP Detection Data of Storage Tank Bottom
下载PDF
导出
摘要 探讨了大型储罐罐底MMO网状阳极的击穿电压和氧气去极化问题。为了探寻罐底板外壁阴极保护的真实阴极保护效果,《钢制石油储罐防腐蚀工程技术规范》编写组对镇海、茂名及上海等地的大型储罐罐底网状阳极和柔性阳极的保护数据进行了实测分析,结果表明,采用MMO网状阳极,其断电电位与通电电位相差很大,MMO网状阳极很难达到-0.85V(CSE)的极化准则;柔性阳极的断电电位与通电电位相差较小,这些都与其阳极反应产物有关。 This paper discusses the breakdown voltage of MMO (mixed metal oxide) net anode and oxygen depolarization for the large-scale storage tank. To find out the real CP effectiveness of external CP of storage tank,the Draft Group of 《The Code of Steel Storage Petroleum Tank Corrosion Control Engineering Technology》carries out an experimental analysis on the protection data of MMO net anode and Anodeflex used in large-scale storage tanks located at Zhenhai, Zhejiang Province, Maoming, Guangdong Province and Shanghai,and the results show that there exist a big difference between switch-off potential and switch-on potential when using MMO anode and it is very hard to reach the polarization criterion at -0. 85 V(CSE) as well; while that of Anodeflex is small,which is close relative to the reaction product of anode.
出处 《油气储运》 CAS 北大核心 2007年第3期16-22,共7页 Oil & Gas Storage and Transportation
关键词 储罐 阴极保护 网状阳极 柔性阳极 数据分析 storage tank, cathodic protection (CP),MMO (mixed metal oxide) net anode, Anodeflex,data analysis
  • 相关文献

参考文献10

  • 1Shreir L L:Corroslon,London,1979.
  • 2胡士信等(译).阴极保护手册(第三版),化工出版社(北京),2005.
  • 3BS 7361 Part1:1991 Cathodic Protection Part 1,Code of Practice for Land and Marine Applications.
  • 4王廷勇.铱钽钛金属氧化物阳极的研究,腐蚀科学与防腐蚀工程技术新进展,化工出版社(北京),1999.
  • 5J T Reding L E Conneally:Mixed Metal Oxide Net Anode System to Provide CP to Tank Bottoms With Plastic Liner Secondary Containment,Corroslon,1990.
  • 6NACE RP 0193:External Cathodic Protection of On-Grade Metallic Storage Tank Bottoms.
  • 7Kevin C Garrity and Philip Simon D:Cathodic Protection Upgrade After Hot Oil Storage Tank Bottom Failure,MP,1994.
  • 8Mohammed Ali & Ali Al-Beed:Titanium Ribbon Anode Grid type Cathodic Protection System for Above Ground Storage Tank Bottoms With Double Containment--A Case Study,Corrosion,1999.
  • 9David H,Kroon:Cathodic Protection for Above Ground Tank Bottoms Pipeline Industry,June 1992.
  • 10API RP 651:Cathodic Protection of Aboveground Petroleum Storage Tanks.

同被引文献136

引证文献13

二级引证文献59

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部