摘要 运用英国声纳公司生产的SONTEST MASTERSCAN340数字型探伤仪和2.5MHz的0°~80°可变角探头,对自行设计制作的8mm厚TA1材质的人工伤试板(通孔型试板、平底槽型试板)和自然伤试板(自然分层型试板)进行了板波探伤的实验研究。研究结果表明,对8mm厚钛板采用板波法探伤是可行的,也是可靠的,且具有探伤工作量小,探伤效率高的优点,值得推广。该方法已在8mm厚ASME SB265 Gr17钛板(约10t)的探伤检验中得到了应用,并得到了用户的认可。同时该试验的成功也表明目前使用的超声波探伤教材中的“小于6mm厚的金属板材可采用板波法探伤”的提法值得商榷。 The ultrasonic inspection for titanium TA1 sheet specimen of 8 mm in thickness (apertured-sheet, trough plate) designed by our self and original defective sheet (laminated) was inspected by SONTEST MASTERSCAN340 digital ultrasonic detector with detective head of 2.5 MHz and 0-80 degree variable-angle made in UK. The results show that The Ultrasonic inspection for Titanium TA1 sheet specimen of 8 mm in thickness is practicable and reliable, and has the advantages of a smaller amount of work and higher efficiency, which is worth to extend applications. This method has been used in inspection of 10 t titanium sheets of 6 mm in thickness and confirmed by the customers.
出处 《稀有金属快报》 CSCD 2007年第3期35-39,共5页 Rare Metals Letters
关键词 超声波 探伤 板波 钛板 薄板 ultrasonic inspection titanium sheet
  • 相关文献

参考文献1

二级参考文献3

  • 1.(GJB494-88).中华人民共和国国家军用标准. 航空发动机压气机叶片用TC11 合金棒材[S].国防科学技术工业委员会,..
  • 2蔡建明.国内外钛合金棒材标准调研报告(内部资料)[Z].北京航空材料研究院,..
  • 3张翥.新型钛合金的发展及应用 [J].金属学报,1999,35(1):35-35.

共引文献13

同被引文献12

  • 1董长升,韩泽龙,赵喜明,冯永琦.航空叶片用TC11合金棒材显微组织对超声波探伤杂波水平的影响[J].金属学报,2002,38(z1):667-669. 被引量:5
  • 2中国特种设备检验协会组织编写.超声波检测[M].北京:中国劳动社会保障出版社,2007.
  • 3李永春,张永红.钛合金板材超声波检测中杂波信号影响因素探讨[J].宇航材料工艺,2012,42(增刊1):144-148.
  • 4Bhattacharjee A,Pilchak A L,Lobkis O I,et al. Correlating ultrasonic attenuation and microtexture in a near-alpha titanium alloy [ J ]. Metallurgical and Materials Transactions A, 2011,42A (8): 2358-2372.
  • 5Zhu Y, Weight J P. Ultrasonic nondestructive evaluation of highly scattering materials using adaptive filtering and detection [ J ]. IEEE Transactions on Ultrasonic, Ferroelectrics, and Frequency Control, 1994, 41(1) : 26-33.
  • 6马小怀,刘金州.钛合金超声波检测中杂波产生原因分析[J].无损检测,2007,27(10):1-5.
  • 7Howard P J, Gilmore R S. Ultrasonic noise and the volume of the ultrasonic pulse [ M ]. Review of Progress in QNDE, vol. 15,Thompson D O,Chimenti D E, eds. New York: Plenum, 1996 : 1495-1502.
  • 8kim J,Udpa L, Udpa S. Multi adaptive noise cancella- tion for ultrasonic NDE [ J ]. NDT & E International, 2011,34 : 319-328.
  • 9Bae S, Kim J, Udpa S S. A new adaptive grain noise cancellation filtering technique [ J ]. Review of Quantitative Nondestructive Evaluation of Materials, 1997, 17 : 759-766.
  • 10司春杰.双晶探头在中厚板探伤应用中应注意的问题[J].无损检测,2011,33(8):75-78. 被引量:3

引证文献1