摘要
针对水轮发电机转子动态接地故障的特点,从制造、检修安装、运行等方面进行了分析,通过对保护装置、外围设备、磁极等进行反复检查、试验,提出建设性的空转测量方法,找出故障点,彻底处理故障,这种特殊的转子接地故障处理经验具有现实指导意义。
In view of hydrogenerator rotor dynamic grounding fault characteristics, analysis is carded out from aspects of manufacture, overhaul installment, operation and so on. Through repeated examinations and tests, constructive proposals for the measurement of no-load operation is given, to find out the fault location and eliminate the fault thoroughly. This special experience of rotor ground fault treatment is of great practical significance.
出处
《大电机技术》
北大核心
2007年第2期15-16,31,共3页
Large Electric Machine and Hydraulic Turbine
关键词
水轮发电机转子
动态接地
处理
hydro-generator rotor
dynamic earth fault
treatment