摘要 扩散敏感梯度磁度的方向及强度是磁共振扩散成像实验的重要参数,但这二个参数不能由用户通过设备自带的软件设定。本文介绍一种新的方法,通过修改MRI扫描机内部的数据文件,用户可以方便与精确地设定扩散加权成像DWI及扩散张量成像DTI的实验参数,而且可以为MRI扫描机增加新的功能. The strength and the direction of diffusion sensitive magnetic gradient field are important experimental parameters in magnetic resonance diffusion imaging, but these parameters cannot be modified by user of the software. A novel method to control these experimental parameters was proposed by modify the data file in MRI scanner and the experimental parameters of diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) can be controlled conveniently and precisely. Furthermore, some new scan functions can be achieved in MRI scanners.
作者 高嵩 包尚联
出处 《中国医学物理学杂志》 CSCD 2007年第2期87-89,101,共4页 Chinese Journal of Medical Physics
基金 国家自然科学基金资助项目(10275003) 北京市共建项目(SYS10001040)
关键词 磁共振扩散成像 扩散加权成像 扩散张量成像 magnetic resonance diffusion imaging diffusion weighted imaging diffusion tensor imaging
  • 相关文献

参考文献7

  • 1唐昕,俎栋林,李德军,包尚联,洪楠,杜湘珂.扩散张量MR成像研究[J].中国医学物理学杂志,2003,20(4):227-231. 被引量:3
  • 2Denis Le Bihan,Peter van Ziji.From the diffusion coefficient to the diffusion tensor[J].NMR in Biomedicine.2002,15:431-434.
  • 3Skare S,Hedehus M,Mosely ME.et al.Condition number as a Measure of noise performance of diffusion rensor data acquisition schemes with MRI[J].J.Mag.Res.2000,147:340-352.
  • 4Jones DK,Horsfield MA,Aimmons A.Optimal strategies for measuring difgfusion anisotropic systems by magnetic resonance imaging[J].MRM.1999,42:515-525.
  • 5Madler B.Whittall KP.MacKay AL.Multiple b-value aquisition of iKn-vivo diffusion tensor images in human white matter brain[C].Proceedings of the 15 th European Experimental NMR Conference (EENC 2000).
  • 6Song AW,Wong EC.Diffusion weighted fMRI at 1.5 T[J].MRM.1996,35:155-158.
  • 7Haglund M,Ojemann G,et al.Optical imaging of epileptiform and functional activity in human cerebral cortex[J].Nature.1992,358:668-671.

二级参考文献33

  • 1P J Basser, J Mattiello, D Le Bihan. MR imaging of fibertract direction and diffusion in anisotropic tissues [J]. Abstracts of the proceedings of the 20th annual meeting of the Society of MRM, New York,1993.585.
  • 2Bammer R, Augustin M, Seifert T, et al. Magnetic resonance diffusion tensor imaging for characterizing diffuse and focal white matter abnormalities in multiple sclerosis[J]. MRM, 44 (4): 583-591 OCT2000.
  • 3C Pierpaoli. Identification of fiber degeneration and organized gliosis in stroke patients by diffusion tensor MRI. Proc[J]. Of 4th 1SMRM Annual Meeting. P563, New York, 1996.
  • 4D K Jones. Full representation of white-matter fiber direction on one map via diffusion tensor analysis[J]. Proc 5th ISMRM Annual Meeting,P1743, Vancouver, 1997.
  • 5T G Reese. Imaging myocardial fiber architecture in vlvo with magnetic resonance[J]. MRM 34, 786-791, (1995).
  • 6M E Moseley, Y cohen, JKucharczyk, et al. Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system [J].Radiology, 1990, 176:439-446.
  • 7G G Cleveland, D G Chang, C F Hazlewood. et al. Nuclear magnetic resonance measurement of skeletal muscle [J]. Biophys J, 1976d6:1043.
  • 8J Mattiello, P J Basser, D Le Bihan. The b matrix in diffusion tensor echo-planar imaging[J]. MRM, 37:292-300 (1997).
  • 9P J Basser, C Pierpaoli. A Simplified method of measure the diffusion tensor from seven MR images [J]. MRM, 39:928-934(1998).
  • 10D K Jones, M A Horsfield, A Simmons. Optimal Strategies for Measuring Diffusion in Anisotropic Systems by Magnetic Resonance Imaging[J]. MRM, 42:515-525(1999).

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部