摘要
桥电125 MW机组自投产以来,3台机组先后出现滑环发热问题,根据连续几年对125 MW机组滑环发热问题的跟踪处理,积累了一些处理方法和经验。文章从三个方面对滑环发热的原因进行了分析,并提出了相应的检查、处理方法。
Through several years' tracking and treatment on 125MW units collector ring heating problem, some solving method and experience has been accumulated. The paper analyzes the reason of collector ring heating from three aspects, and proposes relevant examination and treatment method.
出处
《青海电力》
2007年第1期42-43,共2页
Qinghai Electric Power
关键词
125MW机组
滑环发热
分析
处理
125MW unit
collector ring heating
analysis
treatment