摘要 电力变压器油箱表面的振动信号与变压器绕组及铁心的压紧状况、位移及变形状态密切相关。因此,振动信号分析法是监测电力变压器绕组和铁心状况的有效方法之一。本文利用组建起的变压器振动测量系统,对现场正在运行中的电力变压器油箱表面的振动信号进行了测量,分析了变压器型号、传感器安装位置对所测得的振动信号的影响,结果表明:同型号变压器油箱表面的振动特性相似;油箱表面上下对称位置处的振动特性相差不大,而其它各个位置处的振动信号都没有可比性。最后,本文研究了传感器的安装位置略有变化时,所测得的振动信号的变化情况,提出了应对传感器安装位置进行标记,在进行下次测量时,传感器安装位置最好在标记点处或偏离不超过5cm。本文的研究成果对于振动信号分析法的实际应用具有一定的指导意义。 Steady-state vibration recorded on the tank surface under on-line conditions provides essential information about fixation conditions both for windings and the magnetic core. Therefore, vibration signal analysis method is one of effective methods to monitor the condition of transformer windings and core. In this paper, the transformer vibration measurement system is set up and the vibration signals on the oil tank surface of running transformer in the field are measured. The influences of transformer type and sensor locations to the measured vibration signals are analyzed. The results show that, the vibration characteristics of the same type transformers are similar, and the vibration characteristics at the symmetrical positions on the upside and underside tank surface have little difference. Moreover, the vibration signals measured at other positions have no comparability. Finally, in this paper, the study about the change of vibration signal is carried on when the installed position of sensor is moved a little. It is presented that the installing position of sensor should be marked, and then if the next measurement is taken on, the installing position of sensor should be at the marked point or not exceed 5cm. The results presented in this paper can guide the application of vibration signal analysis method.
出处 《电工电能新技术》 CSCD 北大核心 2007年第2期24-28,共5页 Advanced Technology of Electrical Engineering and Energy
关键词 电力变压器 油箱 振动 传感器 power transformer oil tank vibration sensor
  • 相关文献

参考文献9

  • 1Zalya Berler,Alexander Golubev,Valery Rusov,et al.Vibroacoustic method of transformer clamping pressure monitoring[A].Conference record of 2000 IEEE International Symp.on Elec.Insulation[C].Anaheim,USA,2000.263-266.
  • 2汲胜昌,李彦明.变压器负载条件下提取铁心振动信号基频成分方法的研究[J].电工电能新技术,2003,22(2):64-67. 被引量:17
  • 3汲胜昌,刘味果,单平,李彦明.小波包分析在振动法监测变压器铁芯及绕组状况中的应用[J].中国电机工程学报,2001,21(12):24-27. 被引量:80
  • 4程锦,李延沐,汲胜昌,李彦明,郝韩兵.振动法在线监测变压器绕组及铁心状况[J].高电压技术,2005,31(4):43-45. 被引量:76
  • 5V A Rusov.Monitoring clamping forces in windings and cores of large power transformers using their vibration characteristics[J].Elektricheskie Stanzii (Electric power plants),1998,6:52-57.
  • 6Cipriano Bartoletti,Maurizio Desiderio,Danilo Di Carlo,et al.Vibro-acoustic techniques to diagnose power transformers[J].IEEE Trans.on Power Delivery,2004,19(1):221-229.
  • 7汲胜昌,程锦,李彦明.油浸式电力变压器绕组与铁心振动特性研究[J].西安交通大学学报,2005,39(6):616-619. 被引量:95
  • 8Belén García,Juan Carlos Burgos,Angel Matías Alonso.Transformer tank vibration modeling as a method of detecting winding deformations-Part Ⅰ:Theoretical foundation and Part Ⅱ:Experimental verification[J].IEEE Trans.on Power Delivery,2006,21(1):157-169.
  • 9Ji Shengchang,Luo Yongfen,Li Yanming.Research on extraction technique of transformer core fundamental frequency vibration based on OLCM[J].IEEE Trans.on Power Delivery,2006,21(4):1981-1988.

二级参考文献24

  • 1Zalya Berler, Alexander Golubev, et al. Vibro-acoustic method of transformer clamping pressure monitoring [ A] . Conference record of the 2000 IEEE international symposium on electrical insulation [C]. USA, 2000. 4: 263-266.
  • 2J C Lavalle. Failure detection in transformer using vibrational analysis [D]. Cambridge, MA, USA: MIT, 1986.
  • 3B Weiser, H Pfutzner. Relevance of magnetostriefion and forces for the generation of audible noise of transformer cores. IEEE Trans. on Mag. 2000, 36(5) : 3759-3777.
  • 4A B Madin, J D Whitaker, The dynamic behavior of transformer winding under axial short-circuit forces . Proceedings IEE, 1963, 110(3): 535-550.
  • 5E Reipkinger. Study of noise emitted by power transformers based on today viewpoint [ R]. CIGRE paper, 1988. 8, No.12-08.
  • 6胡昌华,基于MATLA的系统分析与设计.小波分析,1999年
  • 7Mechefske K C. Correlating power transformer tank vibration characteristics to winding looseness[J]. Insight, 1995, 37(8): 599-604.
  • 8Mechefske K C. Assessing the internal mechanical integrity of power transformers using vibration tests[C]. ASEM Joint Power Generator Conference. Honston, Texas, USA, 1996: 953-958.
  • 9Rusov V A. Monitoring clamping forces in windings and cores of large power transformers using their vibration characteristics[J]. Electric Power Plants, 1998, 6: 52-57.
  • 10Sanz-Bobi M A, Garcia-Cerrada A, et al. Experiences learned from the on-line internal monitoring of the behavior of a transformer[C]. Electric Machines and Drives Conference Record, 1997: TC3/11. 1-TC3/11. 3.

共引文献211

同被引文献170

引证文献20

二级引证文献179

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部