期刊文献+

基于TiO_2-Y_2O_3粉体催化发光甲醇气体传感器的研究 被引量:10

Study on Gaseous Methanol Sensor Utilizing Cataluminescence of TiO_2-Y_2O_3 Powder
下载PDF
导出
摘要 发现当甲醇气体通过TiO2-Y2O3(质量比为3∶1)粉体表面时,可被空气中的O2催化氧化产生强烈的化学发光,基于此研制了一种新型的甲醇气体传感器.此传感器对甲醇的检测具有较高灵敏度和较强的选择性.在波长490nm处进行定量分析,催化发光强度与甲醇浓度在一定范围内呈良好的线性关系,其线性范围为25.74~12870mg/m3(r=0.9995,n=8);检出限为8.58mg/m3(信噪比=3).外来物质如正己烷、三氯甲烷、苯、无水乙醇、甲醛、丙酮、氨、甲苯与甲醇共存时,除了丙酮、乙醇和氨分别引起干扰外,苯与其它气体不干扰测定.该传感器工作时间可持续80h以上,是一种长寿命的、性能稳定的气体传感器,并成功地实现了对甲醇气体的实时在线检测. When it passed over the surface of TiO2-Y2o3 with the mass ratio of 3 : 1, methanol gas was catalytically oxidized by 02 in air that resulted in intensive chemiluminescence (CL). A novel methanol gas sensor based on this kind of CL was developed. The results showed that the sensor was of high sensitivity and selectivity to the determination of methanol gas. Quantitative analysis was performed at the wavelength of 490 nm. Under the optimized conditions, the linear range of cataluminescent (CTL) intensity versus concentration of methanol vapor was from 25.74 to 12870 mg/m^3 (r=0.9995, n=8), with a detection limit of 8.58 mg/m^3(the signal-to-noise ratio was 3). No interference signals were observed while the added substances passed through the sensor, such as cyclohexane, n-hexane, chloroform, benzene, ethanol, formaldehyde, acetone, ammonia and toluene, except acetone, ethanol and ammonia. The gas sensor could be working for more than 80 h and showed the longevity and steady performance and was applied to the online determination of methanol successfully.
出处 《化学学报》 SCIE CAS CSCD 北大核心 2007年第6期532-536,共5页 Acta Chimica Sinica
关键词 催化发光 甲醇 气体传感器 TiO2-Y2O3粉体 cataluminescence methanol gas sensor TiO2-Y2O3 powder
  • 相关文献

参考文献9

二级参考文献102

  • 1钟起玲,吴文,李五湖,田中群.电催化甲酸氧化中钯微粒与聚苯胺的相互作用[J].物理化学学报,1994,10(9):813-817. 被引量:9
  • 2吴婉群,万本强,罗维忠.载铂微粒的聚苯胺薄膜电极对甲醇的电催化氧化[J].应用化学,1994,11(2):40-43. 被引量:13
  • 3吴婉群,王月丰,范例,王光荣,李坤兰,刘芹.铂微粒修饰的聚苯胺薄膜电极对甲醛氧化的电催化作用[J].应用化学,1995,12(1):68-72. 被引量:9
  • 4Kohen F., Pazzagli M., Kim J B., Lindner H R, Boguslaski R C. An assay procedure for plasma progesterone based on antibodyenhanced chemiluminescence. FEBS Letter., 1979, 104:201-205
  • 5Pazzagli M. , Bolelli G F. , Messeri G. Homogeneous luminescent immunoassay for progesterone study of the antibody-enhanced chemiluminescence. Serono Symp Publ Raven Press, 1982, 191 -200 through CA97: 4984w
  • 6Kim J B., Kohen F. , Lindner H R. Collins W P. Measurement of plasma progesteroney a solid-phase chemiluminescence immunoassay method. Serono Symp PUBL Raven Presbs, 1982, 201 -206through CA97: 33498z
  • 7Kiohen F. , Kim J B., Lindner H R. Collins W R. Development of solid-phase chemiluminescence immunoassay for plasma progesterone. Steriods, 1981,38:73-88
  • 8Kiohen F. , Kim J B., Linder H R. An immunoassay for plasma cortisol based on chemiluminescence. Steroids, 1980, 36: 421-437
  • 9Lindstrom L., Meuvling L., Loevgren T. The measurement of serum cortisol by a solid-phase chemiluminescence immunoassay. J Steroid Biochem., 1982, 16:577-580
  • 10Schroeder H. R. , Hines C M. , Osborn D.D. Immunochemiluminometric assay for hepatitis B surface antigen. Clin. Chem.,1981, 27:1378- 1384