摘要 本文以专利技术为核心,摒弃传统技术为依托的连续流动分析流路和手工标定方式,避免了分析过程中样品流相互交叉引起的滞后、静态人工标定和动态测量的差别以及流量变化诸因素的影响。经现场运行考核证明,该仪器具有精度和自动化程度高、工作可靠、维护量小、运行成本低等特点。 The text used the patent technique as the core, giving up the way of the continuous based on the traditional technique, the new technique set up the way of the intermittent static analysis flow path and automatic calibration type, avoiding the delayed result produced by mutual interest in the analysis sample flow and the influence of the various factors of difference of the static manual calibration and the moving measurement, and the change of the flow discharge of the sample.Operating result has proved that the instrument is higher precise and higher automatic, reliable performance, less maintains and etc.
出处 《中国仪器仪表》 2007年第3期45-47,共3页 China Instrumentation
关键词 钠离子浓度分析仪 间歇式 自动标定 GD0511Na型 Sodium concentration analyzer Intermittent Automatic calibration