期刊文献+

Determination of captopril in pharmaceutical preparation and biological fluids using two- and three-way chemometrics methods 被引量:1

Determination of captopril in pharmaceutical preparation and biological fluids using two- and three-way chemometrics methods
下载PDF
导出
摘要 Spectrophotometric method has been developed for the direct quantitative determination of captopril in pharmaceutical preparation and biological fluids (human plasma and urine) samples. The method was accomplished based on parallel factor analysis (PARAFAC) and partial least squares (PLS). The study was carried out in the pH range from 2.0 to 12.8 and with a concentration from 0.70 to 61.50μg mL^-1 of captopril. Multivariate calibration models such as PLS at various pH and PARAFAC were elaborated from ultraviolet spectra deconvolution and captopril determination. The best models for this system were obtained with PARAFAC and PLS at pH 2.0. The applications of the method for determination of real samples were evaluated by analysis of captopril in pharmaceutical preparations and biological fluids with satisfactory results. The accuracy of the method, evaluated through the RMSEE was 0.5801 for captopril with best calibration curve by PARAFAC and 0.6168 for captopril with PLS at pH 2.0 model. Spectrophotometric method has been developed for the direct quantitative determination of captopril in pharmaceutical preparation and biological fluids (human plasma and urine) samples. The method was accomplished based on parallel factor analysis (PARAFAC) and partial least squares (PLS). The study was carried out in the pH range from 2.0 to 12.8 and with a concentration from 0.70 to 61.50μg mL^-1 of captopril. Multivariate calibration models such as PLS at various pH and PARAFAC were elaborated from ultraviolet spectra deconvolution and captopril determination. The best models for this system were obtained with PARAFAC and PLS at pH 2.0. The applications of the method for determination of real samples were evaluated by analysis of captopril in pharmaceutical preparations and biological fluids with satisfactory results. The accuracy of the method, evaluated through the RMSEE was 0.5801 for captopril with best calibration curve by PARAFAC and 0.6168 for captopril with PLS at pH 2.0 model.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第4期427-430,共4页 中国化学快报(英文版)
关键词 CAPTOPRIL SPECTROPHOTOMETRIC Parallel factor analysis Partial least squares Pharmaceutical analysis Captopril Spectrophotometric Parallel factor analysis Partial least squares Pharmaceutical analysis
  • 相关文献

参考文献10

  • 1A.Niazi,,A.Soufi,,M.Mobarakabadi. Analytical Letters . 2006
  • 2J.Ghasemi,,R.Amini,,A.Niazi. Analytical Letters . 2002
  • 3A.Niazi. J.Braz.Chem.Soc . 2006
  • 4J.Ghasemi,,A.Niazi,,R.Leardi. Talanta . 2003
  • 5J.Ghasemi,,A.Niazi. Talanta . 2005
  • 6J.Ghasemi,,A.Niazi,,A.Safavi. Analytical Letters . 2001
  • 7H.R.Heel,,R.N.Brogden,,T.M.Speight,,G.S.Avery. Drugs . 1980
  • 8R.Bro. Chemometrics and Intelligent Laboratory Systems . 1997
  • 9J.Ghasemi,,A.Niazi. Analytica Chimica Acta . 2005
  • 10A.Niazi,,J.Ghasemi,,A.Yazdanipour. Analytical Letters . 2005