期刊文献+

Determination of chlorogenic acid by flow injection irreversible biamperometry 被引量:3

Determination of chlorogenic acid by flow injection irreversible biamperometry
下载PDF
导出
摘要 A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum electrode and the reduction of permanganate at another electrode to form an irreversible biamperometric detection system. Under the external potential difference (z^v) of 0 V, in the 0.05 mol/L sulfuric acid, chlorogenic acid can be determined over the range 0.8-120 mg/L with a sample measurement frequency of 80 samples/h. The detection limit is 0.18 mg/L. The proposed method exhibits the satisfactory reproducibility with a relative standard derivation (R.S.D.) of 2.21% for 19 successive determinations of 40 mg/L. A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum electrode and the reduction of permanganate at another electrode to form an irreversible biamperometric detection system. Under the external potential difference (z^v) of 0 V, in the 0.05 mol/L sulfuric acid, chlorogenic acid can be determined over the range 0.8-120 mg/L with a sample measurement frequency of 80 samples/h. The detection limit is 0.18 mg/L. The proposed method exhibits the satisfactory reproducibility with a relative standard derivation (R.S.D.) of 2.21% for 19 successive determinations of 40 mg/L.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第4期431-434,共4页 中国化学快报(英文版)
基金 the National Natural Science Foundation of China (No. 20665001) Guangxi Science Fund (No. 0640029) Innovation Project of Guangxi Graduate Education (No. 2006105930502m33).
关键词 Flow injection Irreversible biamperometry Chlorogenic acid HONEYSUCKLE Flow injection Irreversible biamperometry Chlorogenic acid Honeysuckle
  • 相关文献

参考文献6

  • 1J.Q.Chen,,W.Gao,,J.F.Song. Sens.Actuator,B . 2006
  • 2L.J.Li,,H.Cheng,,W.Y.Huang,et al. Chinese Chemical Letters . 2005
  • 3X.Y.Cai,,Y.L.Liu. Food Sci.Tech . 2005
  • 4X.D.Yuan,,H.L.Koh,,W.K.Chui. J.Pharm.Biomed.Anal . 2005
  • 5M.Namazian,,H.R.Zare. Electrochimica Acta . 2005
  • 6J.V.Garcia Mateo,,A.Kojlo. J.Pharm.Biomed.Anal . 1997

同被引文献40

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部