摘要 发电机内冷水水质不达标及因水质控制不当会引起铜导线腐蚀,近年来已引起发电厂的普遍重视.指出提高发电机内冷水系统的防腐能力的关键是提高内冷水的pH值.通过现场试验,验证了采用RH/RNa/ROH型混床对内冷水进行处理的可行性和有效性. Erosion of the copper wires may occur owing to non-tandard quality and inadequate control of the cooling water of the generator, which has caught the attention of certain power plants. It is put forward that the key to the improvement of the anti-erosion function of the cooling water system of the generator is to raise the pH value of the water. Based on field experiments, the feasibility and efficiency of processing cooling water by using the RH/RNa/ROH Multi-bed Processing method.
出处 《上海电力学院学报》 CAS 2007年第1期65-67,共3页 Journal of Shanghai University of Electric Power
关键词 发电机 内冷水 铜腐蚀 RH/RNa/ROH型混床 pH值 generator water-inner cooling copper erosion RH/RNa/ROH multi-bed pH value
  • 相关文献

参考文献4

二级参考文献6

  • 1K Schleithoff.区发电机冷却水的优化调节[A].火.电厂水处理和防腐防垢技术译文汇编[C].国电热工研究院,1992..
  • 2何绍良.进口水-氢-氢冷大型发电机定子线棒腐蚀堵塞原因分析[A]..第六届电厂化学年会论文集[C].,1999.268-271.
  • 3.GB/T 12145-1999.火力发电机组及蒸汽动力设备水汽质量[S].,..
  • 4望亭发电厂 等.双水内冷汽轮发电机组电气设备[M].北京:水利电力出版社,1978..
  • 5.发电机运行规程[M].北京:电力工业出版社,1981.9.
  • 6曾德勇.水内冷发电机冷却水系统的碱性运行及影响因素[J].中国电力,2001,34(6):24-27. 被引量:21