摘要 目的:探讨经皮椎体成形术的临床应用。方法:对17例23个椎体行经皮椎体成形术治疗骨质疏松症所致椎体压缩性骨折,对5例椎体骨转移性肿瘤行经皮椎体成形术,经皮穿刺至病灶部位,将骨水泥(PMMA)注入病灶。结果:28个手术穿刺部位均成功,术后全部达到止痛效果。椎体压缩性骨折患者术后1d下床活动,无一例发生并发症。结论:经皮椎体成形术安全可行,适用于骨质疏松引起的椎体压缩性骨折及椎体的良、恶性肿瘤,具有强化椎体、镇痛作用,有较高的临床应用价值。
作者 王鸥
出处 《实用医学杂志》 CAS 2007年第6期880-881,共2页 The Journal of Practical Medicine
  • 相关文献

参考文献9

  • 1World Health Organization (WHO).Cancer pain relief and palliative care:report of a WHO Expert Committee[R].Geneva:World Health Organization,1990:1-75.
  • 2Barr J D,Barr M S,Lemley T J,et al.Percutaneous vertebroplasty for pain relief and spinal stabilization[J].Spine,2000,25(8):923-928.
  • 3Deramond H,Depriester C,Galibert P,et al.Percutaneous vertebroplasty with polymethylmethacrylate.Tehnique,indications and results[J].Radiol Clin North Am,1998,36(3):533-546.
  • 4徐宝山,胡永成,郑得志,周静,王林森,徐瑾,唐天驷,倪才方.经皮椎体成形术的实验研究与临床应用[J].中华骨科杂志,2002,22(6):323-330. 被引量:121
  • 5张贵祥,陆军,潘纪青,张悦萍,周根泉,缪竟陶,何之彦.经皮穿刺椎体成形术的临床应用价值[J].中华放射学杂志,2002,36(4):300-304. 被引量:80
  • 6Martin J B,Jean B,Sugiu K,et al.Vertebroplasty:clinical experience and follow-up results[J].Bone,1999,25(2 Suppl):11-15.
  • 7Mathis J M,Barr J D,Belkoff S M,et al.Percutaneous vertebroplasty:a developing standard of care for vertebral compression fractures[J].Am J Neuroradiol,2001,22(2):373-381.
  • 8倪才方,陈珑,徐宝山,杨惠林,胡永成,丁乙,唐天驷,金泳海,邹建伟.椎体内静脉造影在经皮椎体成形术中的应用价值[J].中华骨科杂志,2006,26(1):1-6. 被引量:35
  • 9Belkoff S M,Mathis J M,Erbe E M,et al.The Biomeehanical evaluation of new bone cement for us vertebroplasty[J].Spine,2000,25(9):1061-1072.

二级参考文献16

  • 1陈珑,倪才方,丁乙,刘一之,杨惠林,唐天驷,王以进,金泳海,邹建伟.国产骨水泥行经皮椎体成形术的实验研究[J].中华放射学杂志,2004,38(10):1013-1018. 被引量:15
  • 2Mathis JM,Barr JD,Belkoff SM,et al.Percutaneous vertebroplasty:a developing standard of care for vertebral compression fractures.Am J Neuroradiol,2001,22:373-381.
  • 3Vasconcelos C,Gailloud P,Beauchamp NJ,et al.Is percutaneous vertebroplasty without pretreatment venography safe? Evaluation of 205 consecutives procedures.Am J Neuroradiol,2002,23:913-917.
  • 4Gaughen JR Jr,Jensen ME,Schweickert PA,et al.Relevance of antecedent venography in percutaneous vertebroplasty for the treatment of osteoporotic compression fractures.Am J Neuroradiol,2002,23:594-600.
  • 5Peh WC,Gilula LA.Additional value of a modified method of intraosseous venography during percutaneous vertebroplasty.Am J Roentgenol,2003,180:87-91.
  • 6McGraw JK,Heatwole EV,Strnad BT,et al.Predictive value of intraosseous venography before percutaneous vertebroplasty.J Vasc Interv Radiol,2002,13:149-153.
  • 7Zoarski GH,Snow P,Olan WJ,et al.Percutaneous vertebroplasty for osteoporotic compression fractures:quantitative prospective evaluation of long-term outcomes.J Vasc Interv Radiol,2002,13:139-148.
  • 8Peters KR,Guiot BH,Martin PA,et al.Vertebroplasty for osteoporotic compression fractures:current practice and evolving techniques.Neurosurgery,2002,51 (5 Suppl):96-103.
  • 9Amar AP,Larsen DW,Esnaashari N,et al.Percutaneous transpedicular polymethylmethacrylate vertebroplasty for the treatment of spinal compression fractures.Neurosurgery,2001,49:1105-1114.
  • 10Padovani B,Kasriel O,Brunner P,et al.Pulmonary embolism caused by acrylic cement:a rare complication of percutaneous vertebroplasty.Am J Neuroradiol,1999,20:375-377.

共引文献227

同被引文献16

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部