摘要 采用sol-gel法制备了载钛活性炭,并用于电吸附处理含铬废水。当Cr(Ⅵ)初始浓度为20 mg/L时,载钛活性炭上施加1.2 V的正向电压,电吸附3 h后的处理水水质满足国家排放标准。研究了载钛活性炭电吸附去除Cr(Ⅵ)的影响因素及TiAC的电脱附再生。 Activated carbon modified by titania film (TiAC) was prepared by sol-gel method. When the anode polarization potential on TiAC was 1.2 V and initial concentration of Cr(Ⅵ) was 20 mg/L, after 3 hours electrosorption, the concentrations of Cr(Ⅵ) and total chromium in effluent were lower than national discharge standard. Affecting factors of electrosorption and the electro desorption regeneration of TiAC were also studied.
出处 《环境工程学报》 CAS CSCD 北大核心 2007年第2期59-63,共5页 Chinese Journal of Environmental Engineering
关键词 载钛活性炭 电吸附 Cr(Ⅵ) 电脱附再生 activated carbon modified by titania film electrosorption Cr(Ⅵ) electro desorption regeneration
  • 相关文献

参考文献7

二级参考文献18

  • 1杨凤林,全燮,薛大明,赵雅芝,冯文国,苍郁.水中氯代有机化合物处理方法及研究进展[J].环境科学进展,1996,4(6):36-44. 被引量:23
  • 2施利毅 谢建平 刘函宇 等.一种利用纳米碳管制造电极的电容式海水淡化处理方法[P].CN:1463927A.2003.
  • 3Semiat R, Galperin Y. [J]. Desalination, 2001,140(1):27-46.
  • 4Demircioglu M, Kabay N, Kurucaovali I, et al. [J]. Desalination, 2003, 153 (1-3): 329-333.
  • 5Andelman M. Flow-through capacitor [P]. US:5192432,1993.
  • 6Otowa T. Planar, Flow-Through, Electric, Double-layer Capacitor and a Method of Treating Liguid with Capacitor[P]. US:5538611,1996.
  • 7Oda H, Nakagawa Y. [J]. Carbon, 2003, (41): 1037-1047.
  • 8Odani A, Nimberger A, Markovsky B, et al. [J]. Journal of Power Sources, 2003, 119-121:517-521.
  • 9Cantalini C, Valentini L, Armentano I, et al. [J]. Journal of the European Ceramic Society, 2004, 24(6) :1405-1408.
  • 10Chen J, Li W, Wang D, et al. [J]. Carbon, 2002,(40):1193-1197.

共引文献193

同被引文献180

引证文献14

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部