摘要 针对住宅小区单体建筑多、负荷大、分散、供电距离长等特点,通过对低压电缆供电未端电压降和电缆有功功率损耗的计算,得出一个合理的最大供电负荷和距离,供工程设计人员及业主参考. According to such characteristics as more buldings,heavy load,dispersed residence and long-distance power supply,through the count of low-tension cable terminal loss of voltage and active power loss,the author of the paper achieves a resonable maximum power supply load and distance, which provides references for engineering designers and owners.
作者 任旭升
出处 《河北建筑工程学院学报》 CAS 2006年第4期117-119,共3页 Journal of Hebei Institute of Architecture and Civil Engineering
关键词 低压电缆供电 电压降 有功功率损耗 供电距离 low tension cable power supply loss of voltage active power loss power supply distance