针对住宅小区单体建筑多、负荷大、分散、供电距离长等特点,通过对低压电缆供电未端电压降和电缆有功功率损耗的计算,得出一个合理的最大供电负荷和距离,供工程设计人员及业主参考.
According to such characteristics as more buldings,heavy load,dispersed residence and long-distance power supply,through the count of low-tension cable terminal loss of voltage and active power loss,the author of the paper achieves a resonable maximum power supply load and distance, which provides references for engineering designers and owners.
出处
《河北建筑工程学院学报》
CAS
2006年第4期117-119,共3页
Journal of Hebei Institute of Architecture and Civil Engineering
关键词
低压电缆供电
电压降
有功功率损耗
供电距离
low tension cable power supply
loss of voltage
active power loss
power supply distance