通过对中国石油大庆石化公司化工一厂乙烯老区裂解气压缩机出现的问题及采取的措施进行了简要的介绍和分析,对保证裂解气压缩机长周期运行提出了一些建议。
This paper introduces and analyzes the existing problems in the operation of cracking gas compressor in Daqing Ethylene Unit,such as the corrosive leakage of heat exchangers,scale deposit on compressor rotors or other inner parts,and the jam-up of heat exchangers,etc.,and also advances some advice and ideas for the long-term operation of cracking gas compressor.