利用黑箱和灰箱模型对氯化铵回收三效降膜蒸发系统进行了分析,找到了系统损的关键,即二次蒸汽的消耗引起的外部损.对各效蒸发器采用白箱模型,分析了蒸发器损的主要环节,结果表明,对于一、二、三效蒸发器,传热温差引起的损率分别为77.64%、68.59%和75.87%,降低传热温差引起的损是提高蒸发系统效率的主要途径.由于浓缩热引起的损也是不容忽视的,应提高系统的真空度,采用低温蒸发路线.
Through the exergy analysis of three-effect falling-film evaporation system for ammonium chloride recycle by black box model and grey box model, the main links losing exergy most were found. The external losing exergy mainly concentrated on the consumption of secondary steam. The main links of losing exergy was analyzed by white box model in each evaporator. The results indicate that the losing exergy rates caused by the difference in temperature heat transfer were 77.64%,68.59% and 75.87%, in the first, second and third evaporator, respectively. The method to increase efficiency of evaporation system is to reduce the losing exergy of the difference in temperature heat transfer. As the concentrated heat can also cause the losing exergy, the vacuum degree should be increased and the evaporation system should operate in low temperature condition.
出处
《天津大学学报》
EI
CAS
CSCD
北大核心
2007年第3期377-380,共4页
Journal of Tianjin University(Science and Technology)
关键词
降膜蒸发系统
[火用]分析
氯化铵回收
falling-film evaporation system
exergy analysis
ammonium chloride recycle