摘要 目的:对13例肺栓塞患者的16排螺旋CT各种血管成像进行分析、对比,寻求一种更有效、简便、直观、快捷的成像方法显示肺栓塞。方法:经血管造影(CTPA)后,应用最大密度投影(MIP)、多平面重建(MPR)、容积显示重建(VRT)及仿真内窥镜(VE)成像技术,对于栓塞部位不同者选择不同的层厚(SL)进行图像重建处理。结果:VRT成像对显示肺动脉主干部位的栓塞最为直观,依次为MIP、MPR及VE图像,其中MIP、MPR成像对显示肺叶以下动脉小栓塞情况较好。结论:肺栓塞在16排螺旋CT血管造影后的成像中应以MIP、MPR为主,VRT及VE成像作为一辅助方法。 Objective :To analyze the images of 16-detector multi-slice spiral CT angiography in 13 pulmonary embolism patients in order to find a kind of more valid,easy, fast and simple way to display pulmonary embolism. Methods: Multi-planar reformation (MPR), maximum intensity projection (MIP), volume rendering technique (VT) and virtual endoscopy (VE) were used in the primary imagines of 13 patients who were examined by 16-slices spiral CT pulmonary angiography. The source images were reconstructed in different slices according to the part of pulmonary embolism. Results: VRT was the best way to display the mainly body of the pulmonary artery embolism. The next better one were MIP,MPR and the VE in order. MIP and MPR well displayed the small pulmonary artery embolism which below the lobe of lung. Conclusion : MIP and MPR should take as a lord in diagnosis of pulmonary embolism, VRT and VE will be the assistance methods.
作者 韦力谦
出处 《华夏医学》 CAS 2007年第1期41-42,共2页 Acta Medicinae Sinica
关键词 肺动脉 栓塞 MIP、MPR、VRT、VE成像 pulmonary artery embolism MIP,MPR, VRT, VE imaging
  • 相关文献

参考文献5

二级参考文献37

  • 1Hunsell DM Flower CDR.肺栓塞的影像:应用螺旋CT的新观[J].英国医学杂志:中文版(BMJ),1998,1:6-7.
  • 2[3]Kauczor HU,Ries BG,HeuBel CP,et al. Spiral-CT in der diagnostic der lungenembolie. 1997,12: 78.
  • 3[8]Harvey RT,Gefter WB,Hrung JM,et al. Accuracy of CT angiography versus pulmonary in the diagnosis of acute pulmonary embolism:evaluation of the literature with summary ROC curve analysis.Acad Radiol, 2000, 7:786.
  • 4[10]Nino Murcia M, Jeffrey RB,Beaulieu CF, et al. Multidetector CT of the pancreas and bile duct system: value of curved planar reformations. A JR, 2001,176: 689.
  • 5[11]李松年,主编.现代全身CT诊断学.北京:中国医药科技出版社,2002.512-513.
  • 6[15]Rubin GD.Data explosion:the challenge of multidetectorrow CT.Eur J Radiol, 2000,36: 74.
  • 7[16]Leclerc X, Gauvrit JY, Pruvo JP.Usefulness of CT angiography with volume rendering after carotid angioplasty and stenting.AJR,2000, 174: 820.
  • 8Hunsel D M,英国医学杂志,1998年,1卷,6页
  • 9程显声,肺血管疾病学,1993年,179页
  • 10Kanne JP, Gotway MB, Thoongsuwan N, et al. Six cases of acute central pulmonary embolism revealed on unenhanced multidetector CT of the chest. AJR, 2003,180:1661-1664.

共引文献382

同被引文献28

引证文献6

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部