期刊文献+

Releasing of Cupric Ion of Three types of Copper-bearing Intrauterine Contraceptive Device in Simulated UterineFluid 被引量:3

Releasing of Cupric Ion of Three types of Copper-bearing Intrauterine Contraceptive Device in Simulated Uterine Fluid
下载PDF
导出
摘要 Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order
出处 《Journal of Reproduction and Contraception》 CAS 2007年第1期33-39,共7页 生殖与避孕(英文版)
基金 This study was supported by National Key Scientific and Technological Project(2004BA720A32)
关键词 copper-bearing intrauterine contraceptive device CU-IUD the releasing ofcupric ion simulated uterine fluid flame atomic absorption spectrometer copper-bearing intrauterine contraceptive device Cu-IUD the releasing ofcupric ion simulated uterine fluid flame atomic absorption spectrometer
  • 相关文献

参考文献1

  • 1J. M. Bastidas,N. Mora,E. Cano,J. L. Polo.Characterization of copper corrosion products originated in simulated uterine fluids and on packaged intrauterine devices[J].Journal of Materials Science: Materials in Medicine.2001(5)

同被引文献20

引证文献3

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部