摘要 防雷工作是一项复杂的系统工程,通信基站的防雷措施应建立在综合治理、联合接地、均压等电位的基础上,文中仅就移动通信基站遭受雷击的特点,基站防雷器性能参数的选择,防雷器的安装使用,以及通信基站的一些与防雷相关的外部进线方式进行论述并提出几点建议。 Lightning protection is a complex and systematic project. Lightning protection measures at the communication base station should be based on comprehensive management,joint earthing and voltagesharing equipotential. This paper discusses the characteristics of the mobile communication base station struck by lightning ,the choice of performance parameters of the base station lightning protector ,the installation and employment of lightning protector ,and the way of putting up wires externally concerning lightning protection at the communication base station. On top of that,a few suggestions are put forward.
作者 白洪兴
出处 《河北工程技术高等专科学校学报》 2007年第1期29-31,共3页 Journal of Hebei Engineering and Technical College Quarterly
关键词 等电位 防雷保护 移动通信基站 equipotential lightning protection mobile communication base station