油库防火堤存在的问题及其改进措施 被引量:9

Problems of Oil Depot Firebank and Improvement
下载PDF
导出
摘要 防火堤是油库的重要设施之一,其选型是否正确、质量是否符合要求直接关系到地上油罐储油区安全。文章分析了目前油库所建储罐区防火堤和洞库防护墙在其设置、构造、设计及堤内地面处理和隔油排水设施等方面存在的诸多问题,并结合GB50074-2002《石油库设计规范》和GB50351-2005《储罐区防火堤设计规范》中的规定,提出了具体的改进意见。 Firebank is an important establishment of oil depot. Its structural selection and constructional quality are directly related to the security of ground storage tank farm. This paper analyzes presently existing problems of firebanks in storage tank areas and protecting walls at cave depots, which include their deployment, structure and design, the firebank-enclosed ground treatment and the facilities of water drainage and oil insulation. And based on the provisions of GB50074-2002 'Design Criteria of Petroleum Depot' and GB50351-2005'Firebank Design Criteria of Storage Tank Farm', the paper offers pertinent improvement proposals.
出处 《石油工程建设》 2007年第2期5-9,共5页 Petroleum Engineering Construction
关键词 油库 防火堤 安全隐患 改进意见 firebank problem improvement proposal