摘要
从省煤器产生汽水冲击的原因着手分析,提出消除省煤器汽水冲击现象的方法和省煤器在运行中应注意的问题,指出只有认识了解汽水冲击产生的物理过程及其原因,才可减少汽水冲击事故的发生。
Started with analyzing the causes of steam-water bursting in economizer, the author proposes the methods to eliminate such phenomena and the problems should be noticed in the operation of economizer, and points out that only by realizing physical process and causes of steam and water bursting can man reduce the occurrence of such accident.
出处
《山西建筑》
2007年第11期199-200,共2页
Shanxi Architecture
关键词
省煤器
汽水冲击
饱和温度
economizer, steam and water bursting, saturation temperature