摘要
分析了高原与非高原铁路客车用电取暖器的差异,通过计算及试验验证,确定了青藏铁路客车用电取暖器采用2排加热管、管径为14 mm的技术方案。
The differences in electric space heaters on passenger cars for highland and non-high land railway are analyzed.Through calculation and testing verification,the technical scheme to apply two rows of heating tubes and a tube diameter of 14 mm is determined for the electrical space heaters on Qingzang Railway passenger cars.
出处
《铁道车辆》
北大核心
2007年第4期35-36,共2页
Rolling Stock
关键词
青藏铁路
客车
电取暖器
加热管
Qingzang Railway
passenger car
electrical space heater
heating tube