期刊文献+

前交叉韧带重建移植物的固定 被引量:3

Fixation of Anterior Cruciate Ligament Graft
下载PDF
导出
摘要 移植物的固定是前交叉韧带重建中最重要的环节,也是最薄弱的环节。移植物与骨连接部位的主要生物力学特性是强度和钢度。固定方法有多种,可以因选择不同的移植物或手术方法而不同。界面螺钉固定是目前骨-髌腱-骨(bone-patelar tendon-bone,BPTB)移植物重建前交叉韧带的标准技术。关于肌腱移植物的最佳固定方法并无统一的观点。 Graft fixation is the most important and weakest link in anterior cruciate ligament(ACL) reconstruction. Two main biomechanical properties of graft-bone conjunction are strength and stiffness. There are many fixation methods in the basis the of different grafts and oprative methods selected. Interference screw fixation is consid- ered the standard method for bone-patelar tendon-hnne graft fixation. There remains ambignity about tendon-to-bone fixation. A variety of ACL fixation techniques have been developed to deal with anterior cruciate ligament reconstruction.
出处 《解剖科学进展》 CAS 2007年第1期75-78,共4页 Progress of Anatomical Sciences
  • 相关文献

参考文献27

  • 1Noyes FR,Butler DL,Grood ES,et al.Biomechanical analysis of human ligament grafts used in kneeligament repairs and reconstructions[J].J Bone Joint Surg Am,1984,66:344 -352.
  • 2Markolf KL,Burchfield DM,Shapiro MM,et al.Biomechanical consequence of replacement of the ACL with a patellar ligament allograft.Part2:Force in the graft compared with force in the intact ligament[J].J Bone Joint Surg Am,1996,78:1728-1734.
  • 3Hoher J,Moller HD,Fu F.Bone tunnel enlargement after anterior cruciate ligament reconstruction:fact or fiction?[J] Knee Surg Sports Traumatol Arthrosc,1999,7:215-219.
  • 4Martin SD,Martin TL,BrownCH.Anterior cruciate ligement graft fixation[J].Orthop Clin N Am,2002,33:685-696.
  • 5Clayworthy MG,Annear P,Bulow JU,et al.Tunnel widening in anterior cruciate ligament reconstruction:a prospective evaluation of hamstring and patellar tendon grafts[J].Knee Surg Sports Traumatol Arthrosc,1999,7:138-145.
  • 6Kurosaka M,Yoshiya S,Andrish JT.A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction[J].Am J Sports Med,1987,15:225 -229.
  • 7Johnson LL,Dyk GY.Metal and biodegradable interference screws:comparison of failure strength[J].Arthroscopy,1996,12:452 -426.
  • 8Kaeding C,Farr J,Kavanaugh T,et al.prospective randomized compairsion of bioresorbable and titanium anterior cruciate ligament interference screw[J].Arthroscopy,2005,21:147-151.
  • 9Martinek V,Friederich NF.Tibial and pretibial cyst formation after anterior cruciate ligament reconstrucfion with bioabsorbable interference screw fixation[J].Arthroscopy,1999,15:317 -320.
  • 10Shafer BL,Simonian PT.Broken poly-L-lactic acid interference screw after ligament reconstruction[J].Arthroscopy,2002,18(7):E35 -E39.

同被引文献24

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部