摘要
对南瑞研究院开发的调度员培训系统(DTS)仿真器的暂态稳定计算数学模型与中国电力科学研究院开发的BPA程序进行了比较和分析。通过对两个算例的仿真计算,比较了关于两个程序稳定性的结果。给出了结果之间的差异,并对其产生原因作了阐述。
The mathematical models for transient stability calculation in dispatcher training system (DTS) transient stability simulatior and BPA developed by NARI Ltd. and China Electric Power Research Institute respectively were compared and analyzed. By means of the simulations for two systems, the calculation results of the transient stability were compared. The differences between them were shown, and the reasons causing the distinction were explained.
出处
《机电工程》
CAS
2007年第4期33-35,44,共4页
Journal of Mechanical & Electrical Engineering
关键词
调度员培训系统
电力系统仿真
精度
dispatcher training system (DTS)
power system simulation
accuracy