期刊文献+

Active vibration control of nonlinear benchmark buildings 被引量:1

Active vibration control of nonlinear benchmark buildings
下载PDF
导出
摘要 The present nonlinear model reduction methods unfit the nonlinear benchmark buildings as their vibration equations belong to a non-affine system. Meanwhile, the controllers designed directly by the nonlinear control strategy have a high order, and they are difficult to be applied actually. Therefore, a new active vibration control way which fits the nonlinear buildings is proposed. The idea of the proposed way is based on the model identification and structural model linearization, and exerting the control force to the built model according to the force action principle. This proposed way has a better practicability as the built model can be reduced by the balance reduction method based on the empirical Grammian matrix. A three-story benchmark structure is presented and the simulation results illustrate that the proposed method is viable for the civil engineering structures. The present nonlinear model reduction methods unfit the nonlinear benchmark buildings as their vibration equations belong to a non-affine system. Meanwhile, the controllers designed directly by the nonlinear control strategy have a high order, and they are difficult to be applied actually. Therefore, a new active vibration control way which fits the nonlinear buildings is proposed. The idea of the proposed way is based on the model identification and structural model linearization, and exerting the control force to the built model according to the force action principle. This proposed way has a better practicability as the built model can be reduced by the balance reduction method based on the empirical Grammian matrix. A three-story benchmark structure is presented and the simulation results illustrate that the proposed method is viable for the civil engineering structures.
出处 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2007年第4期487-493,共7页 应用数学和力学(英文版)
基金 Project supported by the Natural Science Foundation of Jiangsu Province of China (No.BK2003083) the Second Batch of "Six Talent Peak" of Jiangsu Province
关键词 NONLINEAR BUILDINGS model identification LINEAR empirical Grammian matrix nonlinear, buildings, model identification, linear, empirical Grammian matrix
  • 相关文献

参考文献7

  • 1Overschee V P,Moor D.N4SID: subspace algorithms for the identification of combined deterministic-stochastic systems[].Automatica.1994
  • 2Hahn J,Edgar T F.An improved method for nonlinear model reduction using balancing of empirical gramians[].Computers and Chemistry.2002
  • 3Kwang S,Lee K S,Eoma Y T,Chunga J W.A control-relevant model reduction technique for nonlinear systems[].Computers and Chemistry.2000
  • 4Hojati M,Gazor S.Hybrid adaptive fuzzy identification and control of nonlinear systems[].IEEE Transactions on Fuzzy Systems.2002
  • 5Ohtori Y,Christenson R E,Spencer B F,Dyke S J.Benchmark control problems for seismically excited nonlinear buildings[].Journal of Engineering Mechanics ASCE.2004
  • 6Cai Guoping,Sun Feng,Wang Chao.Vibrational optimal hybrid control for structural buildings[].Journal of Engineering Mechanics ASCE.2004
  • 7Kamibayashi M,Mita A.Online identification of a building with an active control device[].Advances in Earthquake Engineering.2003

同被引文献15

引证文献1

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部