介绍了底部抗震墙砌体房屋的抗震性能,并从底部抗震墙砌体房屋侧移刚度比的控制、底层框架抗震墙砌体房屋各层抗震能力的匹配、过渡楼层的抗震能力的适当加强等方面阐述了竖向不规则的解决问题,以保证底部抗震墙砌体房屋的安全。
It introduces the quakeproof performance of bottom quakeproof wall brick up building, and represents the solving of the problems of vertical irregularity from the oontrol of side stiffness ratio of bottom quakeproof wall brick up building, the matching of the quakeproof performance of every layer of bottom frame quakeproof wall brick up building, the strengthen properly of the quakeproof performance of transited floor, to assure the safety of bottom quakeproof wall brick up building.
出处
《山西建筑》
2007年第10期94-95,共2页
Shanxi Architecture
关键词
抗震墙
砌体房屋
抗震性能
竖向不规则
quakeproof wall, brick up building, quakeproof performance, vertical irregularity