期刊文献+

磁感应成像系统中相位检测方法研究 被引量:8

Study on technique of phase detection in magnetic induction tomography
下载PDF
导出
摘要 在磁感应成像(MIT)系统中,组织电导率和激励信号与检测信号之间的相位差成正比。为了能对组织电导率分布进行成像,要求系统具有高精度的相位差检测功能。着重研究数字鉴相,包括FFT法、相关法和经典法,并与硬件鉴相方法进行比较。实验结果表明,FFT法和相关法能够较好地区分0.1°水平的相位差,具有误差小、线性度高的优点。数字鉴相为MIT系统鉴相提供了一种更理想的方法。 In the magnetic induction tomography (MIT) system, the electrical conductivity of biological tissue is direct proportion to the phase difference between the excitation signal and the detection signal. To obtain the image of the contribution of tissue's electrical conductivity, the system must have the function of phase detection with high accuracy. The paper focuses on the means of digital phase detection, including FFT method, the correlation method and the classic method, which are ultimately compared with analogue phase detection method. The experimental results show that FFT method and the correlation method, with low error level and high linearity, can better detect the phase difference with the level of 0.1% The digital phase difference detection provides a kind of effective method for MIT system.
出处 《医疗卫生装备》 CAS 2007年第4期11-13,共3页 Chinese Medical Equipment Journal
基金 全军"十一五"重点课题项目(06MA224)
关键词 磁感应成像 数字鉴相 相关分析 模拟鉴相 Magnetic Induction Tomography digital phase difference detection correlation analysis analogue phasedetection
  • 相关文献

参考文献10

  • 1王聪,秦明新,董秀珍,尤富生,李世俊.磁感应方式电导率测量基础研究[J].中国医学物理学杂志,2004,21(3):182-185. 被引量:17
  • 2李世俊,秦明新,董秀珍,尤富生,史学涛,付峰.非接触磁感应脑阻抗断层成像系统设计[J].中国医学物理学杂志,2003,20(1):55-58. 被引量:21
  • 3秦明新,李世俊,董秀珍,等.非接触磁感应脑电导率断层成像系统实验系统研究[A].见:中国科协2003年学术年会文集[C].北京:中国科学技术出版社.2003:314.
  • 4秦明新 ,吕华 ,焦李成 .脑磁感应断层成像[J].国外医学(生物医学工程分册),2005,28(4):218-221. 被引量:2
  • 5Ming-Xin Qin, Li-Cheng Jiao, Shi-Jun Li, et al. A single channel system for brain MIT [J]. Chinese J Biomed Eng, 2004,13(9):47-54.
  • 6S waton, R J Williams. Frequency downconversion and Phase noise in MIT[J]. Physiol Meas, 2002, 23: 189-194.
  • 7S waton, R J Williams. Magnetic induction tomography: phase versus vector-voltmeter measurement techniques [J]. Physiol Meas,2003,24:555-564.
  • 8J Rosell-Ferrer, R Merwa, P Brunner,et al. A multifrequency magnetic induction tomography system using planar gradiometers: data collection and calibration[J]. Physiol Meas, 2006, 27: 271-281.
  • 9白鹏,王建华,刘君华.基于虚拟仪器的相位测量算法研究[J].电测与仪表,2002,39(8):20-22. 被引量:31
  • 10丁康,朱小勇,谢明,钟舜聪,罗江凯.离散频谱综合相位差校正法[J].振动工程学报,2002,15(1):114-118. 被引量:19

二级参考文献23

共引文献82

同被引文献73

  • 1金贵,秦明新,王超,郭万有,徐林,宁旭,许佳.基于PSSMI方法的脑水肿模拟检测实验研究[J].中国医学物理学杂志,2011,28(4):2771-2775. 被引量:4
  • 2李彬,陈武凡.基于模糊聚类空间模型的非均匀MR图像分割[J].医疗卫生装备,2006,27(2):3-4. 被引量:7
  • 3胡晓彦,秦明新,梁文文,张华,焦明克,王芸.基于LabView和Matlab混合编程的脑MIT数字鉴相方法的实现[J].第四军医大学学报,2007,28(12):1144-1146. 被引量:3
  • 4QIN Mingxin, JIAO Licheng, LI Shijun, et al. A single channel system for brain MIT [ J]. Chinese J Biomed Eng, 2004, 13(9): 47-54.
  • 5Qin Ming-xin,Jiao Li-eheng,Li Shi-jun,et d. A single channel sys- tem for brain MIT[J]. Chinese J Biomed Eng, 2004,13 ( 9 ) : 47-54.
  • 6Griffiths H. Magnetic induction tomography[J]. Meas Sci Techn- ol, 2001, 12(8): 1126-1131.
  • 7Gonzalez CA, Rubinsky B. A theoretical study on magnetic ind- uction frequency dependence of phase shift in oedema and hae- matoma[J]. Physiol Meas, 2006, 27(9): 829-838.
  • 8Gonzalez CA, Rubinsky B. The detection of brain oedema with f- requency-dependent phase shift electromagnetic induction [J]. Physiol Meas, 2006, 27(6): 539-552.
  • 9Gonzailez CA, Rubinsky B. Frequency dependence of phase shi- ft in edema: a theoretical study with magnetic induction[J]. Conf Proc IEEE Eng Med Biol Soc, 2005, 4:3518-3521.
  • 10Xi G, Keep RF, Hoff JT. Erythrocytes and delayed brain edema formation following intracerebral hemorrhage in rats[J]. J Neu- rosurg, 1998, 89(6): 991-996.

引证文献8

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部