摘要 Background Long-term efficacy and safety of tacrolimus-eluting stent (Janus) for treatment of coronary artery disease in percutaneous coronary interventions (PCI) "real wodd" is uncertain. The aim of this study was to evaluate the efficacy and safety of Janus stent for treating coronary heart disease in PCI daily practice, the safety of 4-month clopidogrel therapy after Janus stent implantation and the feasibility for treating patients with acute myocardial infarction (AMI) for first time. Methods From February 20, 2006 to August 26, 2006, a total of 200 patients were enrolled and randomly assigned to receive either Janus stent (n=100) or bare metal stent (Tecnic Carbostent, n=100). All patients were administered with clopidogrel for 4 months and aspirin for life long after stenting. Results Baseline clinical and angiographic characteristics were comparable between the two groups. AMI was present in 37% of patients with Janus and 36% with Tecnic Carbostent. At an average of 246-day follow-up, major adverse cardiac events (MACE) was 6% with the Janus stent and 15% with the Tecnic Carbostent (P=0.038). Primary events included 1 cardiac death, 1 myocardial infarction (MI) due to subacute stent thrombosis and 13 target lesion revasculadzations (TLR) due to restenosis in patients with Tecnic Carbostent and 6 TLR due to restenosis in patients with Janus stent. Although all patients had discontinued clopidogrel for an average of 126 days, there was no additional thrombotic event in the two groups. Conclusions Janus stent is efficient in reducing MACE compared with Tecnic Carbostent at an average of 8-month follow-up. Discontinuation of clopidogrel at 4 months after PCI is safe for patients with Janus stent, including AMI patients Long-term efficacy of Janus stent in reducing restenosis requires further study. Background Long-term efficacy and safety of tacrolimus-eluting stent (Janus) for treatment of coronary artery disease in percutaneous coronary interventions (PCI) "real wodd" is uncertain. The aim of this study was to evaluate the efficacy and safety of Janus stent for treating coronary heart disease in PCI daily practice, the safety of 4-month clopidogrel therapy after Janus stent implantation and the feasibility for treating patients with acute myocardial infarction (AMI) for first time. Methods From February 20, 2006 to August 26, 2006, a total of 200 patients were enrolled and randomly assigned to receive either Janus stent (n=100) or bare metal stent (Tecnic Carbostent, n=100). All patients were administered with clopidogrel for 4 months and aspirin for life long after stenting. Results Baseline clinical and angiographic characteristics were comparable between the two groups. AMI was present in 37% of patients with Janus and 36% with Tecnic Carbostent. At an average of 246-day follow-up, major adverse cardiac events (MACE) was 6% with the Janus stent and 15% with the Tecnic Carbostent (P=0.038). Primary events included 1 cardiac death, 1 myocardial infarction (MI) due to subacute stent thrombosis and 13 target lesion revasculadzations (TLR) due to restenosis in patients with Tecnic Carbostent and 6 TLR due to restenosis in patients with Janus stent. Although all patients had discontinued clopidogrel for an average of 126 days, there was no additional thrombotic event in the two groups. Conclusions Janus stent is efficient in reducing MACE compared with Tecnic Carbostent at an average of 8-month follow-up. Discontinuation of clopidogrel at 4 months after PCI is safe for patients with Janus stent, including AMI patients Long-term efficacy of Janus stent in reducing restenosis requires further study.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2007年第7期552-556,共5页 中华医学杂志(英文版)
关键词 drug-eluting stent acute myocardial infarction angioplasty transluminal percutaneous coronary drug-eluting stent acute myocardial infarction angioplasty, transluminal percutaneous coronary
  • 相关文献

参考文献11

  • 1B. Scheller MD,A. Grandt,S. Wnendt,G. Lorenz,M. B?hm,G. Nickenig.Comparative study of tacrolimus and paclitaxel stent coating in the porcine coronary model[J].Zeitschrift für Kardiologie.2005(7)
  • 2Danzi GB,Capuano C,Sesana M,Baglini R,Bartorelli AL,Trabattoni D,et al.Six-month clinical and angiographic outcomes of the tecnic carbostentTM coronary system:the phantom Ⅳ study[].J In vasasive Cardiol.2004
  • 3Bartorelli A,Trabattoni D,Fabbioechi E,Montorsi E,Martini SD,Calligaris G,et al.Synergy of passive coating and targeted drug delivery:the tacrolimus-eluting Janus Carbostent[].Journal of Interventional Cardiology.2003
  • 4Pache J,Dibra A,Mehili J,Dirschinger J,Schomig A,Kastrati A.Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis:a prospective,randomized trial[].European Heart Journal.2005
  • 5Sousa JE,Costa MA,Abizaid AC,et al.Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up[].Circulation.2001
  • 6Moses JW,Leon MB,Popma JJ,Fitzgerald PJ,HolmesDR,O’Shaughnessy C,et al.Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery[].The New England Journal of Medicine.2003
  • 7Yamaguchi T,Nakamura M,Mitsuo K, et al.Percutaneous coronary intervention in acute coronary syndrome[].Journal of Internal Medicine.2000
  • 8Pfisterer,M,Brunner-La Rocca,HP,Buser,PT,Rickenbacher,P,Hunziker,P,Mueller,C,Jeger,R,Bader,F,Osswald,S,Kaiser,C.BASKET-LATE Investigators Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents[].Journal of the American College of Cardiology.2006
  • 9Morice,MC,Serruys,PW,Sousa,JE,Fajadet,J,Ban Hayashi,E,Perin,M,Colombo,A,Schuler,G,Barragan,P,Guagliumi,G,Molnar,F,Falotico,R.A randomized comparison of a sirolimuseluting stent with a standard stent for coronary revascularization[].The New England Journal of Medicine.2002
  • 10Kollum M,Farb A,Schreiber R,et al.Particle debris from a nanoporous stent coating obscures potential antiproliferative effects of tacrolimus-eluting stents in a porcine model of restenosis[].Catheterization and Cardiovascular interventions.2005

同被引文献17

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部