摘要
对直接空冷系统变工况计算进行了研究,提出了直接空冷系统凝汽器压力变工况计算的数学模型。以600MW机组为例,得出了迎面风速、环境温度、凝汽器热负荷对空冷凝汽器压力的影响规律,分析了直接空冷凝汽器的变工况特性,从而为提高直接空冷机组的安全性、经济性和性能提供了有力的理论依据。
Various duty calculations for direct dry cooling system are studied. Mathematical model of variety - duty calculation for ACC (air - cooled condenser) is presented. Take example for 600 MW power plant, the influence of heat loads, ambient temperature and wind velocity on condenser pressure are obtained. Variety - duty characteristics of ACC are analyzed, which provides strong theoretical basis for improving the security, the economical efficiency and the performance of direct dry cooling units.
出处
《水利电力机械》
2007年第4期21-23,共3页
Water Conservancy & Electric Power Machinery
关键词
直接空冷
变工况
空冷凝汽器
特性曲线
direct dry cooling
varying duty
air- cooled condenser
characteristic curve