摘要 分析了ICP-AES法测定塑料中的镉的检测过程,建立了该方法的定量数学模型并推导出不确定度计算公式,找出了该检测过程中的不确定度来源,并且计算了公式中各个变量的不确定度,最后计算出了检测结果的合成标准不确定度和扩展不确定度。 A mathematic model for the ICP-AES determination of cadmium in plastic was established. The calculation formula was deduced. Some data were collected in the procedure of analyzing the plastic sample and the various variable's uncertainties were calculated. The combined uncertainty and expanded uncertainty were finally obtained by synthesizing the uncertainties of various component variables.
出处 《光谱实验室》 CAS CSCD 2007年第2期73-77,共5页 Chinese Journal of Spectroscopy Laboratory
关键词 不确定度 电感耦合等离子体-原子发射光谱法 塑料 Uncertainty,ICP-AES,Plastic,Cadmium.
  • 相关文献

参考文献4

  • 1中国实验室国家认可委员会编.检测和校准实验室认可准则[M].ISO/IEC17025:2005.北京:中国标准出版社,2006.
  • 2国家质量技术监督局计量司组编.测量不确定度评定与表达指南[M].北京:中国计量出版社,2000.
  • 3European Committee for Standardization. Plastics-Determination of Cadmium-Wet Decomposition Method[S]. BS EN 1122 : 2001.London : 2001,1--8.
  • 4国家技术监督局.常用玻璃量器检定规程[S].JJG196—90.北京:中国计量出版社,1990.