摘要
高温高压临氢管道焊缝迅速发生裂纹,国内罕见。文章叙述了高压加氢裂化反应器配对法兰接管焊缝裂纹现象,重点介绍了裂纹的检查检测方法、产生原因及修复检验方案。
It is infrequence in China that the weld of high-temperature and high-pressure hydrogenation pipe is cracked in such short time.The weld crack of mating flange of high-pressure hydrocracking reactor is described in this article,but the focus is on the checking method of crack,crack cause and repaired checking method.
出处
《石油化工设备技术》
CAS
2007年第1期21-24,31,共5页
Petrochemical Equipment Technology
关键词
高温高压
临氢管道
焊缝裂纹
修复
High-temperature high pressure,hydrogenation pipe,weld crack