期刊文献+

装备电缆的故障检测 被引量:1

Equipment Cable Faults Measurement
下载PDF
导出
摘要 装备电缆性能测试和故障检测的方案,基于电桥检测法,以AT89C52单片机为核心,利用X9241代替手动调节的电位器,使用电压比较电路代替常用的电压表实现电桥平衡的自动调节,从而实现测试的全自动化。实验表明通过该方案样机能准确地对电缆故障进行检测。 A method which can be used for equipment cable capability test and faults measurement based on the electric bridge measurement. The AT89C52 is taken as the core, and use X9241 instead of the manual implement. For realizing the self-regulation of the electric bridge, the prototype machine uses the voltage relatively circuit replacing electric meter in common use. So it can realize the automatic measurement. Testing results show that the prototype machine can measure the cable faults in high precision.
出处 《兵工自动化》 2007年第4期91-92,共2页 Ordnance Industry Automation
关键词 数控电桥 装备电缆 自动检测 X9241 Numerical control electric bridge Equipment cable Automatic measurement X9241
  • 相关文献

参考文献3

  • 1孙建涛,魏新劳,陈庆国,王永红.电力电缆故障定点仪的研制[J].电线电缆,2006(2):37-41. 被引量:7
  • 2Argrz,D J.Approximation of the Kin Effect To Improve Cable-Fault Location by TDR[J].Instrumentation and Measurement Technology Conference,2003,(1):20-22.
  • 3Magnago F H,Abur A.Fault Location Using Wavelets[J].IEEE Transaction,1998,13(4):1475.

二级参考文献2

  • 1潘华.电力电缆故障点精确定位方法及其应用[A].全国城乡电网建设和改造研讨会[C].北京:全国电工技术学会,1999,234-241.
  • 2童诗白,华成英.模拟电电子技术基础[M].北京:高等教育出版社,2002.

共引文献6

同被引文献8

引证文献1

二级引证文献4

相关作者