期刊文献+

肝转移瘤CT灌注成像的研究与进展 被引量:1

下载PDF
导出
出处 《放射学实践》 2007年第4期421-423,共3页 Radiologic Practice
  • 相关文献

参考文献24

  • 1Miles KA,Hagball M,Divon AK.Colour Perfusion Imaging:a New Application of Computed Tomography[J].Lancet,1991,337(3):643-645.
  • 2Miles KA,Hayball MP,Dixon AK.Measurement of Human Pancreatic Perfusion Using Dynamic Computed Tomography with Perfusion Imaging[J].Br J Radiol,1995,68 (809):471-475.
  • 3Miles KA,Hayball M,Dixon AK.Functional Images of Hepatic Perfusion Obtained with Dynamic CT[J].Radiology,1993,188(2):405-411.
  • 4Miles KA.Measurement of Tissue Perfusion by Dynamic Computed Tomography[J].Br J Radiol,1991,64(6):409-412.
  • 5Bader TR,Grabenwoger F,Prokesch RW,et al.Measurement of Hepatic Perfusion with Dynamic Computed Tomography:Assess ment of Normal Values and Comparison of Two Methods to Compensate for Motion Artifacts[J].Invest Radiol,2000,35 (9):539-547.
  • 6Materne R,Van Beers BE,Smith AM,et al.Non-invasive Quantification of Liver Perfusion with Dynamic Computed Tomography and a Dual-input One-compartmental Model[J].Clin Sci,2000,99(6):517-525.
  • 7Van Beers BE,Leconte I,Materne R,et al.Hepatic Perfusion Pa rameters in Chronic Liver Disease:Dynamic CT Measurements Correlated with Disease Severity[J].Am J Roentgenol,2001,176(3):667-673.
  • 8Bader TR,Herneth AM,Blaicher W,et al.Hepatic Perfusion after Liver Transplantation:Non-invasive Measurement with Dynamic Single-Section CT[J].Radiology,1998,209 (1):129-134.
  • 9Miles KA,Leggett DA,Kelley BB,et al.In Vivo Assessment of Neovascularization of Liver Metastases Using Perfusion CT[J].Br J Radiol,1998,71(843):276-281.
  • 10史丽静,田建明,毕永民,田军,李树平,陈炜,王敏杰.不同对比剂注射流率下多层螺旋CT肝脏灌注值的比较[J].中华放射学杂志,2005,39(10):1060-1063. 被引量:18

二级参考文献39

  • 1文利,丁仕义,牟伟,周代全,陈洁,张哉根.肝细胞癌CT灌注参数与微血管密度的相关性研究[J].中华放射学杂志,2005,39(3):280-284. 被引量:30
  • 2[1]Eastwood JD,Lev MH,Azhari T,et al. CT perfusion scanning with deconvolution analysis:pilot study in patients with acute middle cerebral artery stroke [J]. Radiology,2002,222(1):227-236.
  • 3[2]Furukawa M,Kashiwagi S,Matsunaga N,et al. Evaluation of cerebral perfusion parameters measured by perfusion CT in chronic cerebral ischemia: comparison with Xenon CT [J]. J Comput Assist Tomogr,2002,26(2):272-278.
  • 4[3]Miles KA,Heyball MP,Dixon AK,et al. Functional images of hepatic perfusion obtained with dynamic CT [J]. Radiology,1993,188(2):405-411.
  • 5[4]Blomley MJK,Coulden R,Dawson P,et al. Liver perfusion studied with ultrafast CT [J]. J Comput Assist Tomogr,1995,19(3):424-433.
  • 6[5]Materne R,Van Beers BE,Smith AM,et al. Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model [J]. Clin Sci,2000,99(6):517-525.
  • 7[6]Cuenod CA,Leconte I,Siauve N,et al. Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT [J]. Radiology,2001,218(2):556-561.
  • 8[7]Miles KA. Measurement of tissue perfusion by dynamic computed tomography [J].Br J Radiol,1991,64(761):409-412.
  • 9[8]Hindmarsh T. Elimination of water-soluble contrast media from the subarachnoid space: investigation with computed tomography [J]. Acta Radiol,1975,346(Suppl):45-49.
  • 10[9]Axel L.Cerebral blood flow determination by rapid-sequence computed tomography [J]. Radiology,1980,137(3):679-686.

共引文献82

同被引文献2

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部