摘要 目的:建立测定过氧化氢产品中总有机碳的方法。方法:采用铂催化法对过氧化氢进行自催化处理,非散射红外吸收法测定过氧化氢中的总有机碳含量。结果:样品前处理简单,测定结果准确度高,精密度好,检测限为:0.1 mg/kg。结论:该方法适用于过氧化氢产品中总有机碳的检测。 Objectlve:To establish a method for detecting total organic carbon in hydrogen peroxide products. Methods:After hydrogen peroxide products were catalyzed by platinum, total organic carbon in it was detected by NDIR. Results:Sample -preparation was simple. The result was accurate and reliable. The detection limit was 0. 1 mg/kg. Conclusion:The method is suitable for determination of total organic carbon in hydrogen peroxide products.
出处 《中国卫生检验杂志》 CAS 2007年第4期645-646,共2页 Chinese Journal of Health Laboratory Technology
关键词 过氧化氢 催化 总有机碳 测定 Hydrogen peroxide Platinum Catalyze Total organic carbon Detect
  • 相关文献

参考文献3

二级参考文献11

  • 1[1]Van Hall,C.E.,Safranko J., Stenger,V.A. Anal.Chem.,1963,35:315
  • 2[2]Beattie,J.Bricker C., Garvin,D.Anal.Chem.,1961,33:1890
  • 3[3]Kieselbach,R. Anal.Chem.,1954,26:1312
  • 4[4]Baldwin,J. M. Mcatee,R. E. Microchem. J.,1974,19:179
  • 5[5]Sharp,J.H.Mar. Chem., 1973,1:211
  • 6[6]Pickhardt,W.P. Oemler,A.N. Mitchell,J.Anal.Chem.,1955,27:1784
  • 7[7]Goulden,P.D. Water Res.,1976,10:487
  • 8[8]Menzel,D.W. Vaccaro,R.F. Linmol.Oceanogr.,1964,9:138
  • 9[9]Erhardt,M. Deep Sea Res.,1969,16:393
  • 10[10]Takahashi,Y. Moore,R.T. Joyce,R.J. Am. Lab.,1972,4:31