摘要 用气浮法对某工业污水处理厂的剩余活性污泥进行了浓缩研究。考察了连续条件下在气浮柱内添加内筒后,内筒的高度和直径变化对气浮效果的影响。用相同的原泥和气浮剂做气浮浓缩对比试验发现,添加内筒后能有效改善出水水质,降低出水中的固体浓度,对浓缩污泥的含水率影响不大,添加内筒后污泥含水率比不加内筒时约低0.3%。内筒直径为50mm时,浓缩污泥的含水率比原泥降低约2.6%,出水中固体浓度从原泥的5141mg·L^(-1)可以降低到39.2mg·L^(-1);内筒高度为1/3时,浓缩污泥的含水率比原泥降低约3.5%,出水中的固体浓度从原泥的3638mg·L^(-1)可以降低到32mg·L^(-1)。 Wasted activated sludge from industrial wastewater treatment plant was thickened by air flotation. An inner silo was added in the flotation device, then the effect of the changes of the diameter and the height of the inner silo on the flotation results were studied. With the same raw sludge and the same flotation chemical, comparison of the flotation results indicated that adding the inner silo can greatly improve the quality and reduced the solid content of the draining. But having an inner silo in the flotation column had little effect on the percentage of moisture of the concentrated sludge. The percentage of moisture of the concentrated sludge concentrated in the flotation column with a inner silo was 0.3 percent less than without it. When the diameter of the inner silo is 50 ram, the percentage of moisture of the concentrated sludge can be 2.6 percent less than the raw sludge, the solid content can be reduced from 5 141 mg · L^-1 of the raw sludge' s to 39.2 mg · L^-1 of the drainage; when the height of the inner silo is 1/3, the percentage of moisture of the concentrated sludge can be 3.5 percent less than the raw sludge ,the solid content can be reduced from 3 638 mg · L^-1 of the raw to 32 mg· L^-1 of the drainage.
出处 《科学技术与工程》 2007年第9期2160-2163,共4页 Science Technology and Engineering
关键词 气浮浓缩 结构参数 剩余活性污泥 flotation concentrate parameters of the structure wasted activated sludge
  • 相关文献

参考文献5

  • 1邱冠周,伍喜庆,王毓华,冯其明,胡岳华.近年浮选进展[J].金属矿山,2006,35(1):41-52. 被引量:47
  • 2孙体昌,崔志广,寇珏,李逢波.废水中氨氮沉淀物的结晶状态及其与捕收剂的作用机理[J].北京科技大学学报,2006,28(3):231-236. 被引量:7
  • 3[4]Chung.Tai Hak Kim Doo Yeon.Significance of pressure and recirculation in sludge thickening by dissolved air flotation.Wat Sci,1997;36(12):223-230
  • 4[5]Kopp J,Dichtl N.Prediction of full-scale dewatering results of sewage sludges by the physical water distribution.Wat Sci Tech,2001;43(11):135-143
  • 5[6]Novak T,et al.Conditioning.filtering,and expressing waste activated sludge.Environ Eng,1999;125(9):816-824

二级参考文献94

共引文献52

同被引文献6

引证文献1

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部