摘要 目的探讨眼前节相干光断层成像(OCT)在LASIK术前角膜厚度测量的精确性。方法分别采用眼前节OCT、超声及光学方法对LASIK术前患者的角膜厚度进行测量,将结果进行对照分析。结果眼前节OCT在LASIK术前角膜厚度测量的结果与超声同样准确,经统计学分析无差异性。结论眼前节OCT可作为LASIK手术前角膜厚度测量的依据,并可作为术后分析观察的方法。 Objective To evaluate the accuracy of measuring central corneal thickness by Optical coherence tomography( SL-OCT ) in LASIK. Methods central corneal thickness were measured by OCT, Ultrasound and Optics. The differences were analysed among the three ways. Results There was no significant difference between OCT and Optics. Conclusion OCT could become the evidence of measuring central corneal thickness before LASIK and the way of analysis and observation after LASIK.
出处 《临床眼科杂志》 2007年第2期133-134,共2页 Journal of Clinical Ophthalmology
关键词 眼前节OCT 角膜厚度 LASIK手术 OCT Central corneal thickness LASIK
  • 相关文献

参考文献4

  • 1Lin X,Ling YL, Luo RJ,et al. Optical coherence tomography in measuring retinal nerve fiber layer thickness in nomal subjects and patients with open-angle glaucoma. Chin Med J, 2001,114 : 524-29.
  • 2刘杏,曾阳发,黄晶晶,郑小萍,凌运兰,蔡小于.相干光断层扫描仪检测正常人及青光眼患者中央角膜厚度[J].中华眼科杂志,2006,42(3):199-203. 被引量:37
  • 3Christopher W, Christiam S, Hans H, et al. Omeal pachymetry mapping with high-speed optical coherence tomography. Ophthalmology ,2002,113 : 444-450.
  • 4Yah Li, Raj Shekhar, David Huang, et al. Noncontact corneal pachymetry with slit lamp-adapted optical coherence tomography.Ophthalmology, 2006,113:799.

二级参考文献15

  • 1段宣初,吴勤,蒋幼芹,卿国平,江冰,石晶明.中央角膜厚度对压平眼压计测量值的影响[J].中国实用眼科杂志,2004,22(10):778-782. 被引量:13
  • 2Muscat S,McKay N,Parks S,et al.Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography.Invest Ophthalmol Vis Sci,2002,43:1791-1795.
  • 3Wong AC,Wong CC,Yuen NS,et al.Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography,Orbscan and ultrasound pachymetry.Eye,2002,16:715-721.
  • 4Bechmann M,Thiel MJ,Roesen B,et al.Central corneal thickness determined with optical coherence tomography in various types of glaucoma.Br J Ophthalmol,2000,84:1233-1237.
  • 5Liu X,Ling YL,Luo RJ,et al.Optical coherence tomography in measuring retinal nerve fiber layer thickness in normal subjects and patients with open-angle glaucoma.Chin Med J,2001,114:524-529.
  • 6Bechmann M,Thiel MJ,Neubauer AS,et al.Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry.Cornea,2001,20:50-54.
  • 7Izatt JA,Hee MR,Swanson EA,et al.Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography.Arch Ophthalmol,1994,112:1584-1589.
  • 8Maldonado MJ,Ruiz-Oblitas L,Munuera JM,et al.Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism.Ophthalmology,2000,107:81-88.
  • 9Ehlers N,Hansen FK.Central corneal thickness in low-tension glaucoma.Acta Ophthalmol (Copenh),1974,52:740-746.
  • 10Munger R,Hodge WG,Mintsioulis G,et al.Correction of intraocular pressure for changes in central corneal thickness following photorefractive keratectomy.Can J Ophthalmol,1998,33:159-165.

共引文献36

同被引文献47

  • 1杨斌,王铮,黄国富,张醇,吴君舒,禤俭环,李春满.中国近视患者的角膜厚度与屈光度关系的研究[J].中国实用眼科杂志,2004,22(7):516-518. 被引量:18
  • 2李坤,陆蓓,崇晓霞,陈彦玲,李晓玲.麻醉剂和泪膜对健康人角膜厚度的影响[J].眼视光学杂志,2004,6(4):244-246. 被引量:16
  • 3周佳奇,褚仁远,周行涛.非接触法测量角膜厚度的临床分析[J].中华眼科杂志,2006,42(8):714-716. 被引量:14
  • 4曾阳发,刘杏,黄晶晶,郑小萍,黄国富,钟毅敏,毛真.三种仪器测量中央角膜厚度的比较[J].中山大学学报(医学科学版),2006,27(4):455-458. 被引量:17
  • 5何燕玲,黎晓新,鲍永珍,刘国栋,胡亦文.Pentacam系统与A超角膜测厚仪测量瞳孔中心角膜厚度的比较[J].中华眼科杂志,2006,42(11):985-988. 被引量:28
  • 6Choi C Y, Youm D J, Kim M J, et al. Changes in central corneal thickness of preserved corneas over time measured using anterior segment optical coherence tomography [ J ]. Cornea ,2009, 28 ( 5 ) :536 - 540.
  • 7Schneider M, Borgulya G, Seres A, et al. Central corneal thickness measurements with optical coherence tomography and ultrasound pachymetry in healthy subjects and in patients after photorefractive keratectomy [J]. Eur J Ophthalmol, 2009,19(2) :180 -187.
  • 8Thomas J, Wang J, Rollins A M, et al. Comparison of corneal thickness measured with optical coherence tomography, ultrasonic pachymetry, and a scanning slit method [ J ]. J Refract Surg,2006,22 (7) : 671 - 678.
  • 9Prakash G,Agarwal A,Jacob S,et al. Comparison of fourier- domain and time- domain optical coherence tomography for assessment of corneal thickness and intersession repeatability[ J ]. Am J Ophthalmo, 2009,148 ( 2 ) : 282 - 290.
  • 10Rosas C H, Li Y, Huang D. High - resolution optical coherence tomography visualization of LASIK flap displacement[J]. J Cataract Refract, 2009,35 ( 9 ) : 1640 - 1642.

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部